horizontal window ac unit installation

How to Install a Portable Air Conditioner In this how-to video, This Old House plumbing and heating contractor Richard Trethewey offers a quick and easy way to cool off a room In this video, This Old House plumbing and heating contractor Richard Trethewey explains how to get air conditioning where window units aren't practical. 1. If there's no existing wall vent, use a jigsaw to cut a 4-inch-diameter hole through an exterior wall. 2. Apply silicone caulk to rear flange on wall vent. 3. From outside, slide wall vent through hole in wall; secure with stainless steel screws. 4. Twist and lock the flexible duct to the exhaust port on rear of air conditioner unit. 5. Connect the duct end to the wall vent and seal with foil duct tape. 6. Plug air conditioner unit into an electrical outlet. 7. Turn on unit, then set thermostat and, if desired, the automatic timer. Installing a portable air conditioner Jigsaw, used to cut vent hole in wall for 4-inch duct.

Caulking gun with silicone caulk 1. Portable air conditioner 3. 4-inch-diameter flexible exhaust duct 4. Foil duct tape, for connecting duct to wall vent 5. 1-inch stainless steel screws, used to secure wall ventSign up to receive special offers and promotions from The Honeywell Store Sign up to Receive Special Offers CONNECT TO US: Social Buzz! View a demo video on this product CLICK SWATCH TO CHANGE COLOR Cools up to 400 Square feet.3-in-1 functions: cooling, fan and dehumidification.Built-in dehumidifier, remove up to 68 pints / 24hours.Latest no-drip technology using an auto-evaporation system.Environmentally friendly R410A refrigerant.24 hr. energy saving programmable timer.Adjustable temperature from 61 to 89 degrees fahrenheit.Powerful air flow 174 CFM (4.9 CMM).Single 3.94 ft hose.Hose diameter measures 5 in. Window bracket can be installed either vertically or horizontally and is adjustable from 19.9 to 47.25 inches.

Minimum Noise level of 50 dBA. Included in the box: 1 Honeywell MN10CESWW portable air conditioner, installation accessories, instruction manual, and remote control. Honeywell Portable Air Conditioner -Stay cool. The MN10CESWW 10,000 BTU Honeywell Portable Air Conditioner combines 3-in-1 technology into one compact body, cooling and dehumidifying areas up to 400 square feet. It features an environmentally friendly refrigerant, auto evaporation system, a reliable dehumidifying function as well as a traditional three-speed, fan-only function. The MN10CESWW is a convenient portable air conditioner that delivers optimum cooling, dehumidification and fresh ventilation.Unlike a fixed air conditioner unit, the Honeywell Portable Air Conditioner requires no permanent installation and the smooth-gliding caster wheels provide easy mobility from room to room. What's more, the auto- evaporation system allows for hours of continuous operation with no water to drain or no bucket to empty. This portable air conditioner comes with everything needed including a flexible exhaust hose and an easy-to-install window venting kit.

The window vent can be removed when the unit is not in use.Air Conditioner Mode10,000 BTU portable air conditioner cools areas up to 400 sq. ftQuiet operation (50dbA)R410A environmentally-friendly refrigerantAuto-Evaporation System: Collected water from cooling is removed automatically.
small ac unit for bathroomNo bucket, no-drip design (this operation depends on the humidity level at your location) Fan Only ModeGently circulates air even when air conditioner cooling is not neededDehumidifier ModeRemoves excess moisture from air (Ideal for areas with high humidity like basements)Dehumidification capacity up to 68 pints per 24 hoursContinuous Drain System: Connect a standard garden hose tube to continuously drain water collected when using in Dehumidifying ModePortable DesignEasy-to-install window venting kit included with adjustable window bracket (from 19.9 to 47.25
electric ac and heating unit

inches) Smooth gliding castor wheels easily roll unit from room to roomAdditional FeaturesQuick & Easy Installation-all installation parts includedMultiple Fan Speeds: High, Medium, Low174 CFM powerful air flowWashable filter-helps catch unwanted dust particles in the airDigital LED display with feather touch controlsProgrammable Timer (Set to turn ON/OFF in advance from 1 to 24 hours)Full function remote control5-Year Limited WarrantyWhat's in the Box1 MN10CESWW 10,000 BTU Honeywell Portable Air Conditioner 1 Remote Control (batteries included) 1 Owner's Manual & Warranty
domestic ac unit Limited 1 year parts and labor for unit and additional 4 year parts for Room Coverage in Sq. Ft.: Maximum Air Flow (CFM):of Fan Only Speeds: Lowest Sound Level (Decibels): Click Here to Write a Review for this Product. Honeywell MN10CESWW Portable Air Con Manual Ordering a large quantity? Click the image below to

send a bulk order request to our friendly sales staff who can create a quote and provide personal service for your order! Enter the information requested below and our sales staff will respond in 1-2 business days. (Monday through Friday 8am-5pm CST) Please include as much detail as possible with your request:Installation Guide for PTACs Designed for a wide range of applications, packaged terminal air conditioner units are ideal for hotels and motels, office buildings, schools and apartments. When installing a Zoneline packaged terminal air conditioner or heat pump, the following checkpoints should be followed to reduce future problems. Wall case must be level from left-to-right. Wall case must be level from front-to-back (1/4 bubble slope to rear is acceptable if rear drains are used. Case must be level if internal drain is used). Wall case should extend at least 1/4″ to the outside for caulking. Wall case must be sealed/caulked to outside wall on all four (4) sides.

Wall case should be sealed/caulked to the inside wall on all four (4) sides. Standard steel wall cases are 42″ W × 16″ H × 13 3/4″ D. 16″, 24″, 28″ and 31″ deep cases are available for thicker walls. Wall case must be installed 3″ to 5″ above floor. Wall case must extend at least 2 3/8″ into room. Sub-Base can be used for electrical connections (check NEC & local codes for compliance). Electrical sub-bases are available in 208/230-volt 15, 20 & 30-amp configurations; 265-volt available in 15, 20, & 30-amp configurations. Remote Wall Thermostat (Optional) Zoneline Heat pumps require 6 wires (min) for remote wall thermostat hook-up. Zonelines with electric heat and cooling require at least 5 wires for digital remote thermostat hook-up. Standard digital and programmable digital thermostats are available for both heat pumps and electric heat models. 208/230-volt applications use power cords for wall receptacle or sub-base applications.

265-volt applications must be direct connected per NEC. Architectural-3-colors available: Beige, Maple, & Bittersweet Chocolate. Architectural-Extruded anodized aluminum (can be painted to match outdoor motif). Stamped-Standard louvered aluminum grille available. Older architectural grilles can be used if RAK40 baffle kit is installed on chassis. Architectural grilles made by others must have 65% free area. These grilles must have properly located baffles/deflectors or RAK40 kits must be installed on chassis. Grilles not supplied by GE Appliances must be approved by a GE Appliances Applications Engineer to ensure compatibility. Zonelines operated during construction should be cleaned prior to property opening. Unless properly cleaned, drywall and construction dust will coat the interior of the units and create unwanted odors and dust in the rooms, generating guest complaints. Drywall and construction dust may set off room fire alarms when the electric heaters are energized.