Safety 1st, KidTrax Battery-Powered Ride-On Vehicles RecalledSafety 1st, KidTrax Battery-Powered Ride-On Vehicles Recalled...More International Comfort Gas Furnace/AC UnitsAirquest, Arcoaire, Comfortmaker, Heil, Keeprite, Kenmore, ICP Commercial, and Tempstar Brand Names AffectedInternational Comfort Products LLC recalled gas furnace and AC units. The unit's control board can ignite and can result in the ignition of flammable mater...More HP, Compaq Notebook Computer Batteries RecalledHP, Compaq Notebook Computer Batteries Recalled...More Chrysler, GM, Kia, HyundaiChrysler, GM, Kia, Hyundai...More A.O. Smith, Reliance, Apollo, State, Maytag Water HeatersA.O. Smith is recalling about 5,000 75-gallon propane gas water heaters. The water heaters can accumulate soot on the burners, posing a fire hazard....More Dole Salad MixAn outbreak of E. coli disease in Minnesota has triggered a nationwide consumer alert about three brands of Dole salad mix. Consumers were issued a warning... Noisy indoor unit, air handler, or furnace are all very common complaints in the HVAC field.
But they usually fall into one of six different categories listed below. Some of these noises can also be caused by your air vents. For more information on this topic, click below... Loud scraping, metal hitting metal sound Loud thumping or vibrating noise Rattling, squealing or high-pitched sound Loud pop or bang sound First of all, turn the system off immediately. This is usually the worst of the six different sounds. One cause for this sound is that the blower wheel came loose from the motor shaft, moved and is hitting the blower housing. In this case, if no damage was done to the wheel or the motor shaft, it could be moved back to the proper spot and re-tightened to the motor. Another and more likely cause is that the blower wheel actually broke, in which case it would need to be replaced. This makes a very disturbing sound almost as bad as fingernails on a chalk board. A third possibility is that a motor mount broke, causing the entire motor and blower assembly to drop and the blower wheel is hitting the housing.
In any case, please shut off the system ASAP when this sound is heard or the repair bill could significantly increase. Sometimes this sounds like an out of balance washing machine. This is usually a blower wheel out of balance. Sometimes the motor itself can become out of balance as well. york ac parts phoenixThe sound isn't usually too bad but shouldn't be ignored because it can cause other problems to the system.split ac unit service If the unit is working fine then most likely it is just a noisy transformer. ac units for sale in azSome transformers are louder than others and they all hum to some degree. If the unit is not working and a hum can be heard, it could be a bad indoor fan motor and/or capacitor. This applies mostly to Heat Pumps.
This is usually refrigerant-flow related, such as a check valve, and it's not always a problem. Some units have noisy check valves or metering devices. If the sound gets louder or annoying and the air filter has been checked, then a service call should be placed. This usually happens when the system fan first starts and/or stops. This is also only found on systems with sheet metal ductwork, and it is usually from the return trunk. When the fan first starts the duct pops in from the negative pressure of the fan. When the fan shuts off, the pressure releases and the duct pops-out. This could be a sign of undersized duct, a clogged filter, closed vents or flimsy duct; (For Gas or Oil-fired systems) Very Important: If you hear an unusual rumbling sound associated with combustion from your gas or oil-fired appliance, call for service immediately. This indicates what could be a serious problem with the burner portion of your appliance. Turn off equipment if necessary. Out of balance blower wheel
Noisy refrigerant check valveTempstar® Dealers in Wilmington, DE Area Now you can enjoy optimum comfort with our efficient packaged gas furnace and electric air conditioner product that delivers reliable temperatures every season and reduced humidity during the hot months. It is ENERGY STAR® qualified, which means efficient year-round comfort. 14 SEER/12 EER cooling 81% AFUE heating (products manufactured after 1/1/15) Quiet performance (as low as 73 decibels)* Multi-speed blower motor for improved temperature and humidity control Durably built to withstand weather and debris Designed for corrosion resistance and lasting performance 3-Year No Hassle Replacement™ Limited Warranty+ Lifetime Heat Exchanger Limited Warranty1 Efficient single-stage scroll compressor Efficient multi-speed ECM blower motor Corrosion-resistant stainless steel heat exchanger Reliable, direct spark gas ignition System protecting highand low-pressure switches
Wire hail guard grille and raised coil design for protection against weather and debris Corrosion-resistant tin-plated copper evaporator coil tubing Sound reducing features: vibration-reducing top panel, soft mounted compressor and blower motor Compatible thermostat: heat/cool with humidity sensing Rooftop or ground level installation Cooling capacity: 2–5 tons Heating capacity: 40,000–130,000 BTUh Residential & 3-Phase Small Package Products Warranty (French) Residential & 3-Phase Small Package Products Warranty Spanish SPP Full Line SPP Mainline AC - PAR5/PGR5, PGS4/PAD4 *Quietest size within each model group during most common cooling operating condition. No Hassle Replacement™ Limited Warranty: If compressor, coil or heat exchanger fails due to defect during the applicable No Hassle Replacement limited warranty time period, a one-time replacement with a comparable unit will be provided. 10-Year Parts Limited Warranty: Timely registration required for 10-year parts limited warranty.