air handling unit connection details

Whether you require indoor or outdoor Air Handling Units, side-by-side or stacked AHUs, roof or floor-mounted AHUs we can assist Designed for installation in ceiling voids, Barkell's high-efficiency heat recovery solutions are ideal for commercial applications such as banks, shops & offices Our air handling units are used across a diverse range of applications & sectors including hospitals, universities, retail stores & data centres Whatever the application, our experienced engineers will work in partnership with you, to ensure that we design the unit to meet your specification Barkell's air handling equipment is manufactured in accordance with this specification and includes details of other features available Our air handling unit configuration and AHU sizing guide enables you to rapidly select the appropriate unit size for a specific project requirement We offer Computational Fluid Dynamics (CFD) services which help to gain an indepth understanding of thermal behaviour within a facility

Barkell AHUs – Finding the right solution for your application Our Air Handling Units serve a range of customers across healthcare, education, data centre, retail and commercial environments. We understand the importance of business critical cooling and through our versatile range of AHU units and using the latest technology, we offer bespoke and flexible air handling units which provide increased efficiency, system reliability and reduced operating costs.
ac unit not working properlyPackaged compact supply air handling units for applications needing automatic supply tempered air ventilation with integrated controls.
air conditioner window unit weightChoice of LPHW, electric and DX.
amps for ac unitIdeal for roof mounting, plant room or ceiling void applications.

Very quiet – 25mm double skinned panels provide better acoustic and thermal properties over conventional AHU’s. Reduce installation time – all components are pre-assembled, wired and tested before despatch. Units are delivered in sections where applicable. Simple precise commissioning – minimum and maximum ventilation rates precisely set and limited at AHU requiring no throttling dampers. Energy efficient controls – all models have Ecosmart controls built in (non control options available) providing the most energy efficient and cost effective solution. Part L and energy efficient – motors are IE2 to BS 5000 direct drive and high efficient belt drive. Long lasting – manufactured from highly rigid pentapost design framework with heavy gauge aluzinc panels proving a corrosive resistant shell. 5 year warranty – for peace of mind. No control options have a 2 year warranty Air handling unit shall consist of fan, G4 filter and electric heater battery, DX or LPHW.

Air handling unit shall be constructed with double skinned aluzinc panels on an aluminium Pentapost frame. Air handling unit shall incorporate full Ecosmart control package and constant pressure control. Units will be supplied in modular sections for on-site assembly by the installer; this will also necessitate completion of the wiring between modules. The fan unit will have a 5 year warranty. For no control units contact Nuaire. Leisure and Sports Facilities Surgeries & Medical Centres I&M Ecosmart Boxer AHUI&M Ecosmart Boxer AHU (Fan speed control only)I&M Ecosmart Boxer AHU BMS Controls Addendum to 671188I&M Ecosmart Boxer AHU with Constant Pressure ControlsI&M Ecosmart Boxer Errection/Assembly - sizes 3 to 7I&M Ecosmart Boxer with Electric Heater/A guide to adjusting Electric Heater outputI&M Ecosmart Boxer Air Handling Units Connection of Heat Exchanger Bypass DamperEcosmart Boxer Consultants Specification If this is not exactly what you are looking for, try one of these products instead.

BESPOKE AIR HANDLING UNITS Nuaire has a long and successful history in heat recovery and has been developing and manufacturing AHUs for many years. BOXER bespoke AHU solutions can be tailor made to suit any application requirements and can include humidification, cooling, heating and filtration and now up to 20m3/s. Wide range of energy efficient heat recovery units with optional integrated controls with a duty range up to 5m3/s.The requested URL /ccb/VA/VAASC/VA%2023%2073%2000.doc was not found on this server.To help develop this article, click 'Edit this article' above. Air handling units (AHU, sometimes referred to as ‘air handlers’) form part of the heating, ventilating and air conditioning system (HVAC) that supplies, circulates and extracts air from buildings. Air handling units can be supplied in a range of sizes, and with a variety of capabilities, but typically they comprise an insulated box that forms the housing for; filter racks or chambers, a fan (or blower), and sometimes heating elements, cooling elements, sound attenuators and dampers (that can be operated manually or automatically to regulate or prevent specific air flows).

In some situations, such as in swimming pools, air handling units might include dehumidification. Heating and / or cooling can be generated within the unit itself, or can be provided by connection to the building’s boilers or chillers. Generally, air handling units will be connected to the ductwork within the building that supplies air to and extracts air from the interior, but they can be used to supply and extract air direct to a space, or they may be located on a roof (rooftop units or RTU). Air handling units that consist of only a fan and a heating or cooling element, located within the space they are serving, may be referred to as fan coil units (FCU). Air handling units can be used to re-circulate a proportion of ‘stale’ air within a building, mixing this with fresh air to reduce the amount of air conditioning that is required. They can also include heat recovery, recovering heat from return air and using it to warm the supply air. Fans may be single speed, may have a range of set speeds, or may be variable frequency drive.

Flow rates may also be controlled by inlet vanes or outlet dampers. Air handling units generate noise (and vibration) which can be disruptive, and this can be compounded where ductwork passes between acoustically separate spaces. In this case, acoustic attenuators might be used. In addition, vibration can be generated. This vibration can be isolated by inserting flexible sections between the unit and ductwork and by isolating the unit from the building structure. Where air handling units are located outside buildings, they can be the source of complaints by neighbours because of the noise and vibration they generate and sometimes because of odours they expel (typically where they are serving kitchens). It is important that these units are properly designed, installed and maintained to minimise this disturbance. ‘Wet’ systems, that include water evaporative cooling, can present a hazard to health. Businesses using such systems are required to carry out a risk assessment and put in place procedures to ensure there is no risk to public health.