york ac unit reviews

Writing about York central air conditioner is hard. That is normal, first step is always hard. You need to get something out of your chest – right? What do you have in store for York? Let me guess, it is surprise. I’m pretty sure York does to. Before we surprise York central ac units, let go over rules. So – are we really to write?How satisfied were you with York central air conditioner? Please enter the word that you see below. York International Corp. is one of the oldest companies. It first connection with refrigeration equipment was in 1903. York Manufacturing Co. was found on September, 1874 in York, Pennsylvania by six men. These six men were Jacob Loucks, Robert L. Shetter, Stephen Morgan Smith, George H. Buck, Henry H. LaMotte, and Oliver J. BollingerThese six men form a partnership in 1885 and Stephen Morgan Smith become it first president. This the year the company introduced its first ice machine. This ice machine was known as the Jarman Ice Machine. Jarman Ice Machine was capable of producing eight tons of refrigeration and was sold to customers in Mississippi.
George Jarman was the person, who started with the ice machine development. best rated residential hvac unitsThe first development was just the beginning for York Manufacturing Co. York International markets their central air conditioner units under the brand names Coleman, Luxaire, and York. can you turn a window ac unit on its sideIt sells central air conditioner units and furnace for residential, light commercial and other hvac unit for industrial.how to mount a window ac unit Central Air Conditioner Reviews Here are lists of other central air conditioners review by consumers and homeowners. You Got Questions                                      We Got Answers How was YOUR York central air conditioner?
Do you need advice about your York hvac? or tell us how long had you have York air conditioners without major problem? What the Title for Your York's Question or Review What had been happening to YOUR York Ac? Upload A Photo Of The Ac Units(optional)[ ? ] Add a Picture/Graphic Caption (optional) Click here to upload more images (optional) To receive credit as the author, enter your information below. (first or full name) (e.g., City, State, Country) Check box to agree to these  submission guidelines. (You can preview and edit on the next page) Read Other Visitors Question and Review Click below to see some great reviews on York central air conditioner When temp rises outside, cold air stops getting produced inside My central ac unit is approximately 5 years old, but has been used actively for 4 years (it was installed in a new condo - we are the first owners). Condenser Rusted and Freon Leaked We bought our home 11 years ago which makes our York HVAC 22 years old.
Our central air conditioner unit while old has worked well until a recent power … York Hvac Take Too Long To Remove Humidity The cooling aspect is A+++; With a new Honeywell programmable thermostat the selected degree of cooling is exact. However in the morning my hygrometer … Intermittent compressor Recently my York central air conditioner unit 2.5 ton was working tirelessly on an extremely hot and humid day. I noticed the air coming from the register … Inside Fan Stays On When Compressor Goes Off Our York package unit is about 15 years old. We purchased the house with it. At the suggestion of our maintenance company we had the contact switch … Consumers Beware Of NFNMO76006  This was a tragedy waiting to happen for me and my family. In 2005 my home was refurbished and a YORK Air conditioning unit was put on my home. My York Central Air Conditioner is only 4 years old and it does not work  March 6, 2011 My York Central Air conditioner is only four years old and it does not work.
I have no heat for the last few days. When I turn the … 9 Year Old York Central Ac We have zone heating/ac in our 9 year old home. The York Hvac unit for the upstairs worked ok for about 5 years but has had repair service every year since. Central Air Conditioner Is Cooling Intermittently.  I purchased a foreclosure home 9 months ago. The central air conditioner is a 3 ton York unit split type. House & A/C is 5 years old but has 3.5 years … York Central Ac Unit Report  York Model EVV 89876 has been installed for about 12 -14 years. It has performed well and has had one capacitor failure, not bad. As far as the outdoor … York LX Compressor Failure New central air conditioner system installed 7/1/10 by a factory authorized dealer and on 7/8/10 the compressor failed. Dealer said the unit was shipped … Is My York Central AC Need Replacing It was working fine one then the next day it would not run. The fan would turn on but no cold air. I opens the panel and the wires on top of the switch …
Any info on my central air conditioner model I just bought my home a few months ago and thought I should have the central ac checked before I started using it this summer. The house has electric … Poor York Unit and Masco and Sons Contractor Was Not rated yetRegarding Model H2RD048S06B, Serial W0D7613648, This was a replacement unit for another York installed three summers ago. The first central ac unit started … York HVAC will blow cold then goes to room temperature. We have a 9 years-old 2 central air conditioner unit 13.5 SEER/3.5 TON York HVAC system (smaller unit for downstairs; bigger unit for upstairs). Return to central air conditioner and refrigeration cycle from York central air conditioner review< 12 3 45 > 2 posts, read 33,961 times Originally Posted by Earl B Bryant is actually a brand now owned by Carrier. Bryant isn't a bad brand but then again I contend that there aren't very many bad brands since all of them use similar parts manufacturers for the most part.
Here's a list of HVAV brands and their history. All brands may not be up to date but the vast majority are. Some of the common one: AMANA: Formerly a division of Raytheon, now part of Goodman Manufacturing. GOODMAN MFG: Started by contractor Harold Goodman in 1982, purchased from the Goodman family in 2004 by Apollo Management, now owned by Goodman Global. BRYANT: Founded by Charles Bryant in 1904, now division of Carrier Corp-United Technologies. CARRIER: A wholly owned subsidiary of United Technologies. PAYNE: Started by D. W. Payne in 1914, later becoming part of BDP with Bryant and Day & Night. Now a Carrier brand name. AMERICAN-STANDARD: Became Tappan Air Conditioning division in 1972. American-Standard purchased the Trane Company in 1984. American-Standard name revived in 1988. In 2007, American-Standard spun off WABCO, sold the plumbing division and changed the corporate name to Trane in November. GENERAL ELECTRIC: HVAC division purchased by the Trane Company in 1982.
TRANE: The Trane Company purchased GE's climate control division in 1982. Trane was purchased by American-Standard in 1984. In 2007 American Standard spun off non HVAC lines and will be changing the corporate name to Trane. Now owned by Bermuda based Ingersoll Rand. YORK: Formerly a dvision of Borg-Warner, York International is now spun off. York also makes Fraser-Johnson, Luxaire, Moncrief, Winchester, Coleman-Evcon, AirPro, Red T. Also known in the past as Central Environmenal Systems. York was purchased by Johnson Controls in 2005. COLEMAN: Heating division started in 1958. Bought by MacAndrews & Forbes Group in 1989, by Beacon International using the name Evcon Industries in 1990, by York International in 1994. RHEEM: Rheem Manufacturing is owned by Japanese water heater manufacturer Paloma. RUUD: Part of Rheem Manufacturing. Instead of worrying about the brand trying looking this over and then call contractors and see who is willing to go through it line-by-line and help you get the best system you can have for the money you're looking to spend.
2,401 posts, read 2,971,174 times In my area, goodman has probably more than half of the market share. It's only logical that there would be a significant number of complaints. How many of those complaints are real quality issues, versus installation issues is the question. Hvac tradespeople are legendary in the art of butchery & b.s, so I'd surmise that most issues with goodman units are the result of installer-butchery and not quality related. The parts are all warrantied for at least ten years anyway, so it's not like the customer would be out anything but labor in the event of premature failure. Originally Posted by hueyeats This is absolutely an installation problem, not a brand issue. Any idiot can install a "more powerful" unit in your home- cooling a house off "twice as fast" means that "more powerful" unit is probably way too large. That isn't a good thing. A/c units are sized by their cooling capacity - a "3 ton" goodman is just as "powerful" as a 3 ton carrier.
Replacing a 3 ton unit with say, a 5 ton unit might cool your house off faster, but your energy costs will rise & the house will never have an even temperature throughout. You'll also have more humidity & a better chance of growing some mold. And in addition adding a "more powerful" unit doesn't mean you'll actually get what you're paying for. For a unit to actually be "more powerful" it will need to move that required amount of air. The formula is 400 cubic feet of air per minute per ton which is set by the ARI standard. The other condition to meet the tonnage rating is 67�F indoor wetbulb, 80�F indoor drybulb and 95� outdoor ambient temperatures at sea level. This also is what correlates to the RLA or rated load amperage. Too many time I see people saying the amperage isn't meeting the RLA so something must be wrong. They don't seem to understand that if the system is in conditions outside of standard conditions then that influences the amount of work required. 3 Ton unit - 1,200 CFM
2.5 Ton unit - 1,000 CFM 2 Ton unit - 800 CFM People just assume their ducts can handle whatever they feel like installing. This fails on many levels because if the system was designed for a 2 Ton system then the duct work is designed for a 2 Ton system and the chances that it will handle the airflow need for a 3 Ton system are nearly zero since most HVAC system duct work is already undersized for the system that it was originally designed for. 4,327 posts, read 13,419,270 times Originally Posted by maggiekate You want to know what the ironic part is? When looking at spec sheets comparing Trane and Goodman the Goodman units are consistently 800 - 1000 btu higher given all the same conditions. What that means is that Goodmans are more efficient and transferring heat than the Trane units are. The reasons vary but the main reason is the thickness of the materials that are used in the Trane units compared to the Goodmans. Trane uses thicker materials and has a coil that tries to make up the difference that is a spun-fin coil compared to the traditional type of condenser coil.