Advent A/C Frequently Asked Questions Related Models & KeywordsQuestionAnswerSupporting Documents ACRG ACRG11 Electric Heat I have an electric heat strip. Which do I need, ACRG or ACRG11? You need the ACRG. I have a LP furnace. You need the ACRG11. I only have 4-5 wires between thermostat & A/C, how can I get your (Advent) to work? +12V DC & GND to the upper unit plus 8 wires between thermostat and upper unit are required. One additional wire is needed if using a LP furnace. I have 6 wires between A/C & thermostat; can I eliminate medium fan and one other to get it to work?This will not work. My portable generator will not start the Advent AC. Can I install a third-party Quick Start Kit?Quick start kits are not required for Advent Air systems. This would indicate your generator is not powerful enough for the AC system. Modification of the Advent AC unit is not recommended and will void the warranty. Use of a larger generator would be recommended.

ACTH ACTH11 E-2 Code The thermostat is flashing E-2 on the display and nothing is working. The freeze control is either open or not connected properly. If the purple wire is not connected, this will cause this as well. How do I identify the ACRG from ACRG11? Remove air filter cover to expose product label. I am replacing a Coleman upper unit with an Advent upper unit and I don't want to run more wires. You will need to use the Advent to Coleman interface kit, ACCOLKIT. This only applies if the rest of the Coleman system is functional. I am replacing a Carrier upper unit with an Advent upper unit and I don't want to run more wires. You will need to use the Advent to Carrier interface kit, ACCARKIT. This only applies if the rest of the Carrier system is functional. My knobs on the ceiling assembly won't stay ON; it looks like the shafts are too short. This would indicate that the ceiling assembly is not properly installed. Make sure to install using all screws to keep it flat.

If the inside ceiling has a radius, this can cause the assembly to bow as well.
ac unit canada Is the Advent thermostat (ACTH/ACTH11) analog or digital?
ac history units year 6 The ACTHG & ACTH11 are both analog thermostats that have a digital display.
how much does the average ac unit cost After I shut my thermostat to OFF, why won't it come back when I switch it to ON again right away? There is a 3 minute delay period before the compressor will be allowed to run again. ACTH ACTH11 Cooling Temperature It's currently 98º outside. I have my thermostat set to 70º, but it will only get down to 77º. Is my AC unit defective? No. A properly sized AC unit will cool 18-22º below the ambient temperature. 77º is within that range and indicates your AC unit is operating normally for the current temperature conditions.