276 posts, read 746,924 times 7,475 posts, read 16,253,628 times 9,123 posts, read 34,300,328 times Originally Posted by Hoot Owl Is the house actually reaching the set temp? You could be low on refrigerant? If not, it could be the relay switch @ the compressor. Condenser units are notorious for collecting leaves and other debris and some of it could be effecting the switch and/or the condenser itself- not allowing for enough heat molecule transfer. Or it could be the T/stat itself, as mentioned before. 605 posts, read 3,859,011 times 14,070 posts, read 39,900,025 times 3,785 posts, read 15,674,846 times 3,191 posts, read 6,970,571 times Originally Posted by crazyma It's the inside blower in the closet (attached to the furnace) that's acting up. Not sure which brand it is. Tell your husband that the fan is now turning on and off with the compressor - like it should be doing. Not sure why, for a day, it ran constantly.Look forward to your reply.

82 posts, read 438,721 timesForced air heating or cooling air handler troubleshooting: blower fan won't shut off: This article describes what to check if the furnace or forced air blower fan does not stop when you expect it to do so
1 ton window ac buy onlineThese same diagnostics also aid in air conditioning blower assembly diagnosis when an A/C blower continues running.
carrier ac parts dealers in delhiWe explain what switches or controls may be set improperly or what else, such as a shorted wire, can cause continuous HVAC fan operation.
auto body shop in miami florida First, confirm that the room thermostat is not calling for heating or cooling. In the heating season, just set the thermostat(s) to the lowest setting and confirm that room temperature is above that point.

In the cooling season do the opposite - set the thermostat to its highest setting and confirm that room temperature is below that point. You have told the thermostat to turn off the HVAC equipment. If the equipment was running give it three to four minutes to shut down. Next: If the blower just keeps running no matter what, there are two places to check switch settings before calling your heating or air conditioning service company in response to a furnace fan or air conditioning fan that just keeps running without stopping: 1. At the room thermostat: the FAN-AUTO-OFF or FAN ON/OFF switch on the room thermostat should be checked. The fan control should be set to AUTO. You can try turning the switch to OFF too. Details of checking the thermostat's FAN-AUTO-OFF or FAN-ON switch position when the furnace (or air conditioning) fan won't stop running are at FAN WONT STOP - THERMOSTAT SWITCH Other snafus such as a shorted thermostat wire can also cause the A/C or warm air furnace fan to run continuously.

Those problems are explained at THERMOSTAT WON'T TURN OFF. 2. At the furnace or air conditioner air handler or blower unit: the FAN LIMIT SWITCH may include a switch that manually keeps the fan running. We discuss this switch here. Take a look at the fan limit control switch. Before pulling the cover off of the switch, just see if the switch includes a control such as the white push-pull switch like the white device shown at the lower left in our photo. Depending on the position of this switch (pushed-in or pulled out) the fan may be on manual override - causing the fan motor to run continuously. Check the printing on the switch face to see if you should push the switch in or pull it out to leave the blower on "Auto". ("Man" or "Manual" would be forcing the fan to run.) Usually: "Push-in" position on this (Honeywell) fan limit switch is for continuous fan operation and "Pull out" position is for automatic fan operation. There are some reasons (explained

at BLOWER FAN CONTINUOUS OPERATION) to leave the blower fan on continuously for long periods, such as to use an air filtering system to improve indoor air quality. And in some buildings we may run the blower continuously for more even or better conditioned (heated or cooled) air distribution. On the off chance that someone has inadvertently mis-connected or shorted fan control wires at the fan limit switch, also check out FAN LIMIT SWITCH INSTALLATION. On the chance that there is a shorted thermostat wire, a problem that can also cause the A/C or warm air furnace fan to run continuously see THERMOSTAT WON'T TURN OFF. Details about the manual FAN ON or FAN AUTO ON switch right at the furnace or air handler at the manual at BLOWER FAN CONTINUOUS OPERATION. This article series answers most questions about central heating system troubleshooting, inspection, diagnosis, and repairs. We describe how to inspect, troubleshoot and repair heating and air conditioning systems to inform home owners, buyers, and home inspectors of common heating system defects.

My fan keeps running with no heat on furnace. What can I do? If the furnace does not even try to run, that is if it never even starts, then follow these steps: If the furnace tries to start but cannot keep running then there is a different problem such as no fuel or an unsafe condition. See DIAGNOSE & FIX HEATING PROBLEMS-FURNACE - home A complete list of oil and gas fired furnace controls is at FURNACE CONTROLS & SWITCHES Continue reading at FAN LIMIT SWITCH or select a topic from the More Reading links or topic ARTICLE INDEX shown below.Written Normal ACs (non inverter) work in the following wayThe AC compressor runs continuously till set temperature is reached in the roomThe compressor then switches off, but the blower fan in the wall mounter unit keeps running. Durint this time the AC fan blows air out at Room temperature (which feels warmer)When temperature of room rises then compressor starts running again. During theis period the air coming out from the inner uny is cooled by the condenser coilsAnd the process is repeated.... as long as you keep AC runningAc works this way throught the operation period.

Now if you feel that your AC keeps switching off and on very frequently check the followingYour AC may be over powered for room *for example a 1.5 ton AC installed in a scenario where 1 ton is enough)If there is voltage fluctuation in your area then the compressor may keep shutting don on large voltage swingsSolution: Get a StabilizerYou have set the temperature setting too high. Max temp suggested for ACs is 25 degree Celsius, any higher will mean the compressor shuts down often. Remember every compressor shutdown and startup draws a high starting currentSet AC temperatures between 22 and 24 degrees CelsiusThe thermostat/ Temperature sensor is faultyGet unit inspected by Authorized technicianThere is dust buildup on the outer unit / compressor unit. The dust buildup may cause overheating by preventing efficient heat exchange, This may lead to overheating of compressor and it shuts down to, prevent damage to itselfGet unit serviced by Authorized technicianThe fan motor of the outer unit is not working properlyGet unit inspected by Authorized technicianRemember to get the AC serviced at least thrice a year to ensure smooth operationCool Thoughts...

Written Its simply coz when the compressor is on you get the cold air.When compressor is of you get hot air.In the cycle fan keeps on running in standard ACs and compressor works on/off cycle.Written Sounds like your Thermostat satisfies but leaves the fan on to keep circulation going. If this happens without much time between cycles you might want to find large heat sources or opening to the unconditioned spaces which could cause short cycling. There is also the possibility you have an oversized unit or the thermostat is going bad.Written You should put it on auto. That way when the temperature reaches whatever it is set on it will stop.I am thinking you have central ac so correct me if I am wrong. I have had my share of problems with ac units over the years and it is a must for Miami. My ac unit just clicked on and the air comes right on me.If all else fails read the directions. I will show a picture of the thermostat box and explain how it works. I wish I was there because I could show you in a second.