low profile air handling unit

Indoor and Outdoor Small Air Handler 400 to 8,500 Nominal Cfm 39SH – Indoor Horizontal – 400 to 8,500 Cfm 39SV – Indoor Vertical – 800 to 4,000 Cfm 39SR – Outdoor – 800 to 8,500 Cfm 39SM – Indoor Modular – 1,600 to 8,500 Cfm Carrier 39S low pressure air handler units are designed for vertical and horizontal installation with a variety of airflow configurations. These units provide a practical and low cost approach for comfort conditioning requirements in a variety of construction applications. Carrier’s AHUBuilder® software makes selecting and optimizing the 39S air handler easy. Learn from the Experts @ Carrier UniversityProducts » Indoor Air Handlers & Fan Coils » Indoor Air Handlers and Fan Coils The Indoor Air Handling (IAH) units include belt driven fans designed for air conditioning and/or heating buildings or specified spaces. They are developed to meet commercial applications such as schools, medical facilities, and office buildings.
The Low-Profile Fan Coil (LFC) is a forward curved low cost, dual wall constructed blower coil unit. Performance capabilities range from 300 to 4,700 cfm and up to 3.5 in. wg. The LFC is available in eight compact sizes. Unique features are listed below. * Ultra-low profile - as low as 11 inches * Accessibility - dual side access * One inch double wall construction - provides superior IAQ * Internal neoprene isolation - dampens internal vibration * Stainless steel drain pan - insulated double wall * Internal flex connection Unique Accessories for Model LFC: * Internal spring isolation - lowest profile units on the market * Pre-filters - 2-inch 30% (MERV 8) or 4 inch 65% (MERV 11) efficiencies (vertical only) (1/4 turn fasteners standard for quick access) * Coils - hot water, steam, chilled water, and direct expansion (total of 8 rows) * NEMA 1 disconnect switch The Modular Small Cabinet Fan Forward Curved (MSCF-FC) and Modular Small Cabinet Fan Backward Inclined (MSCF-BI) are low-profile, dual wall, modular constructed, essentially a custom mini air handler.
Performance capabilities range from 300 to 4,700 cfm and up to 4 in. wg. The MSCF units are available in eight compact sizes. * Modular design - easy to install * Accessibility - dual side access to each module * Stainless steel drain pan with insulated double wall * Pre and/or post filters - 2-inch 30% (MERV 8) or 4-inch 65% (MERV 11) efficiencies, or 4-inch 95% (MERV 15) efficiencies (vertical and slopped) * Coils - hot water, steam, electric, chilled water, and direct expansion * Re-heating coils - hot water and steam * Pre and/or post plenums - 12 or 24 inch access for mounting controls * Mixing Box - with or without filters, dampers, and actuators The Vertical Fan Coil (VFC) is a vertical forward curved, dual wall constructed unit. Performance capabilities range from 300 to 3,500 cfm and up to 3.5 in. wg. This unit is available in seven sizes. Unique Accessories for Model VFC: * Internal spring isolation * Pre-filters - 2-inch 30% (MERV 8) or 4 inch 60% (MERV 11) efficiencies (vertical only) (1/4 turn fasteners standard for quick access)
* Coils - hot water, steam, chilled water, and direct expansion (total of eight rows for sizes 600-800 and ten for sizes 1300 and up)what is air conditioner split system Indoor Air Handling Units (Model MSCF / LFC / VFC)car ac leak smell Low-Profile Fan Coil (Model LFC) (#464496 IOM) Modular Small Cabinet Fan (Model MSCF) (#462888 IOM)Vertical Fan Coil (Model VFC) (#464696 IOM)ac unit in a tent Low Profile Fan Coil Units (Model LFC)Low Profile Modular Indoor Air-Handling Units (Model MSCF)Vertical Fan Coil Units (Model VFC) Technical InformationWhite Pages for Modular Small Cabinet Fan (construction features, dimensional data, wieghts, performance, and technical data on various options and accessories) Configured Model Selection CAPS required to Create
Static Model Download Now WarrantyWarranty Statement for TAP products Cabinet — Powder coat painted. Matching discharge plenums and decorative supply and return air grilles are available for use when units are to be installed within conditioned space. Motor—Inherently protected motors are mounted inside of insulated cabinet to reduce motor noise. A choice of motor horsepowers and drive combinations are available to allow you to meet specified CFM at various static pressures up to 2" [.498 kPa] external static pressure. Low Profile — Allows for horizontal installation in most standard drop ceiling applications, and the movement of units through most standard doorways for addition or replacement work. Thermal Expansion Valves — Standard all models. Filters — One inch [25 mm] throwaway filters are standard, but filter racks are designed to accept either one inch [25 mm] or two inch [51 mm] filters. Evaporator Coil —Two circuit, interlaced row split coils are constructed with copper tubes and aluminum fins mechanically bonded to the tubes for maximum heat transfer capabilities.
All coil assemblies are leak tested up to 450 PSIG [3100 kPa] internal pressure prior to installation into units. Refrigerant Connections — Field piping connections are made through a fixed post between two side access panels on either side of the unit. Allows flexibility to meet most field conditions as well as full accessibility after the installation is complete. Units may be used with two straight cool condensing units or single circuit manifolded in the field using the copper fittings shipped with each unit. The RHGL Air Handler has not been tested, rated or certified to operate with dual remote heat pumps. Drain Pan —The galvanized steel drain pan is designed to trap condensate in either vertical or horizontal installations. Condensate drain connections are located on both sides of the unit allowing complete flexibility to meet most field conditions. Service Access —Two removable panels on top and each side of the unit are easily removed for access to motors, blowers, sheaves, and filters.