in cab ac unit

Contact for pricing details Click Here for Financing Info 6000 Watt Markon/Cummins Generator Remote Oil Filter & Cover Safety Interlock All Welded Aluminum Radiator Diamond Plate Locking Cover Under Bunk Unit/HVAC, Charger & PDM Centramatic's APU's, air conditioning and heating systems are specifically designed for use in the trucking industry. Use of such systems for cab comfort and convenience comply with anti-idling laws and use roughly 75% less fuel as compared to idling the trucks primary engine. Increasing air quality legislation and local enforcement, coupled with soaring fuel costs have greatly increased APU demand. Click to find out about our financing options. Engine Detail: Designed with 4 cycle, 2 cylinder water cooled Kubota Diesel. Lube oil capacity of 4 qts., average diesel consumption is 0.16 gal./hrs./per kilowatt hr. Recommended normal oil change interval of 500 hours. Microprocessor controls glow plugs to automatically cycle.
Starting system is 12 volt. High capacity oil filter is remote mounted. Extended life, washable, reusable K&N air filter is located for easy access; also contains noise isolation foam baffle. In addition, for added cooling capacity, an all-welded aluminum high capacity radiator is mounted outside on vibration isolators with rock guard protection and airflow is provided from a five-blade engine driven reverse air flow cooling fan. This unit operates independently of the truck Freon or cooling systems. Diesel fuel system is comprised of a mechanical primary and electrical self-priming lift pump with a self-indicting fuel filter. Generator: Markon/Cummins belt driven 6000 watt, 120 volt brushless generator; rated for continuous duty. Automatic Shut Down: Microprocessor controlled high temperature and low oil pressure automatic shut downs are built in for system protection. Battery Charger: Connected to the truck battery. Power available for battery charging and electrical accessories;
60 amp, 12 volt solid state. Block Heater: APU can supply AC power to the electric block heater if the truck engine is so equipped. Auto Start: Allows for unattended automatic battery monitoring and charging. Remote Control Module: Allows remote operation of APU from the sleeper and monitoring of all AC circuit breakers status by LEDs. Shore Power Module: Allows full function of cab conveniences through 30 amp RV shore power source. Power Distribution Module (PDM): Mounted in sleeper; provides AC power from the 6000 watt generator or the Shore Power module and is distributed through the PDM circuit breakers to the charger, HVAC unit, block heater and accessories. Cover: Polished Diamond Plate Cover with door lock. User Friendly: Product comes with required installation hardware and instructions to complete most installations. 30 inches of under-cab or frame access will be required for installation. The lockable access door provides security and easy access for checking oil levels, fuel filter, drive belt tension, and starting the unit from outside.
Total system weight: 560 lbs Heating: Fully electrical, thermostatically controlled. Runs off the APU or Shore Power. Heat provided by 2500 watt heat strips. Ventilation: Is provided by a multi-speed high capacity 450 cfm blower to reduce air stratification in sleeper. Air Conditioning: Fully electric space saving split system. Evaporator/compressor is located inside with an outside mounted condenser. Runs off the APU or Shore Power with 14000 BTUs cooling, produced by a high capacity 110 volt electric compressor.ac outdoor unit prices Digital Thermostat: Conveniently located in sleeper to thermostatically control heating, ventilation and air conditioning.how to fix a carrier ac unit Actual rating will vary with options, operating conditions,sam's ac unit
Simple, Reliable and Trucker Tough Remote Shore Power Hook-UP Locking Diamond Plate Cover with Steps +1 800 289-8282SupportDealer LoginDealer Search Dynasys SL APU for Day Cabs and Sleeper Cabs Introduced Dynasys™ APUs are intelligently designed to provide dependable, energy-efficient performance with convenient service intervals that match scheduled truck maintenance. Each unit is backed by a two-year/4000 hour warranty with an option to extend coverage.You are hereApplications » Fleet + Work Trucks Solar Solutions for Heavy Duty Trucking can breathing freon from a leak in indoor ac coils cause health issues? in a condo, have an outside ac unit with 'air handler' in my laundry room, with coils I assume freon runs thru from outside (they get cold). Had the fan motor replaced and the tech had to add a pound of freon, commented could be a leak in the "inside coils" and may need to add more freon in a couple of years. Didn't think anything of it at the time, but have allergies, and my congestion is worse now the ac is back on than during the 3 weeks when I had the windows open with fans, and that doesn't make sense.
Wondered if I'm breathing freon, and that could be the issue?Technician says there is a leak in the evaporator coils indoors. Air is pushed through the cooling coils and into the living space of the home. We breath that r-410a coolant. The manufactured evaporator coil is 2 years old. We have spent over $1400 repairing low coolant problems without replacing the evaporator coils. We now see that is the problem that needs replacing. A 2 year old unit..? The manufacturer Nordyne refused to warranty at 1 year 2 days. Family health not an issue if it isn't their family...same goes for the repair service company. They didn't mention that accumulation indoors is a heath issue for occupants. Where is our protection? Here is a link to an MSDS for it - you can read for yourself on the toxicity and side effects. Basically, has not been found to be toxic or cancer causing, but breathing it can cause a number of effects as is says under the Inhalation item, and when it contacts heated surfaces like a furnace or water heater flame is can for acids.
It also carries a lubricant with it in the air conditioning system (commonly mineral oil) and vaporized oils are known to be a significant respiratory hazard, both chemically and because the aerosolized oil coats the lungs causing edema and gradual suffocation./_Uploads/dbsAtt...======However, if leaking a pound every yesar or few, unlikely to have a noticeable effect unless you are breathing right at the leak point. I would say more likely, the respiratory effects are from inadequate filtration of dust and lint that is being recirulated in your home, or from mildew/mold growth on the evaporator coils. That is a common source of respiratory issues, as is forced air ventilation in general because it tends to pull inand recirculate more allergens from outside and inside than direct electric or steam/hot water radiator or baseboard systems. No it can not hurt you at all. The only way refrigerent can harm you is by inhaling it directly into the lungs, which can cause frostbite and kill you.
The only thing its hurting is your wallet and the ozone layer.The only way its harmful is by burning the freon directly with a flame. A furnace is not hot enough to burn leaking freon. Phosgene gas is produced when freon is burned. It will turn a yellow torch flame green during that process which I have seen many times before. If you breath in the fumes from the green flames "Phosgene gas" it can kill you instantly. Phosgene gas is also found in Mustard Gas which has been used as a chemical weapon since WW1.There is no way for a homeowner to come in contact with Phosgene gas unless the furnace or house is on fire and you are standing at or above the evap. coil at the very second the coil begins to melt releasing the gas. If you are not there right at that second trying to inhale the stuff it just gets burned up by the rest of the fire/flames.Freon is 100% safe to homeowners. Source: 15 yrs exp. the ceiling are cracking in my house is it safe to live here? I have an acrid odor in my living area which I cannot find the source.