Two locations where a cold air return should be installed: a. Open area of wall and low to the ground. b. Behind appliances and high on the wall. c. Open area of wall and high on the wall. d. Behind appliances and low to the ground. Which of the following is a law of thermodynamics: a. Heat is a form of matter. b. Heat moves toward a place with higher intensity. c. Heat moves toward a place with lower intensity. d. Heat moves toward a place with a higher temperature. Sensible heat describes _________________________. a. How fast heat will travel. b. The quantity of heat. c. The volume of heat. d. How hot something feels. Latent heat measures _______________________. a. The temperature of heat in a substance. b. The quantity of heat in a substance. c. The velocity of heat in a substance. d. The heat potential of a substance. Latent heat is measured in ____________________. a. Degrees Celsius, F ahrenheit and Kelvin
b. International System of Units c. British Thermal Units d. Board of Trade Unit If 1 pound of water warms to 60 degrees F from 55 degrees F, what btu of latent heat will it have absorbed? What is the amount of heat energy required to evaporate 1 pound of water? In an air conditioning and refrigeration system, what occurs in an evaporator? a. The refrigerant absorbs the latent heat. b. The refrigerant evaporates latent heat. c. Latent heat is condensed.9 ton ac unit d. Latent heat is released.on the wall air conditioning units In an air conditioning and refrigeration system, what occurs in a condenser?excessive condensation on ac unit b. The refrigerant releases the latent heat. c. Latent heat is pressurized.
d. Latent heat is increased. In a sealed system, pressure and temperature _________________. a. are inversely proportional b. go in opposite directions up and down d. follow each other up and down Which of the following is not a type of compressor? In Fahrenheit, the boiling point of water is _____________. To change Fahrenheit to Celsius, which formula is used? a. C =(F+32)÷ 1.8 b. C=(F-32) x 1.8 c. C=(F-32) ÷ 1.8 Which of the following is not a method by which heat may be transferred from a warmer substance to a colder substance? What btu of heat is required to raise 1 pound of ice 1 degree F when the temperature is below 32 degrees F? What btu of heat is required to raise 1 pound of steam 1 degree F above the temperature of 212 degrees F? A day-ton of refrigeration is the amount of refrigeration produced by melting 1 ton of ice at a temperature of 32 degrees F in 24 hours. Ice exerts pressure ________________.
d. In all directions Pressure is usually measured in ___________. a. Pounds per square foot b. Pressure per square foot c. Pounds per square inch d. Pressure per square inch Atmospheric pressure, at sea level, is 14.7 psia. When one rises into the atmosphere, the atmospheric pressure decreases by 1 psi for every_________________. Vaporization can be increased by _____________ the pressure on a liquid. Every mechanical refrigeration system has __________ different pressure levels. Pressure on the high pressure side of a mechanical refrigeration unit is called _______________. b. discharge or head pressure c. differential l pressure The exertion of pressure on a substance with a constant temperature increases its volume in proportion to the increase in pressure. HVAC technician certification and licensing exams test knowledge and skills related to specific HVAC processes and applications. Many states require technicians who work on heating, ventilation, cooling and refrigeration equipment to be licensed.
Learn more with  or take a free HVAC Practice Exam.Crane Drops HVAC Unit From 28-Story Building in NYC; ENERGY STAR Version 3 Certification Training for HERS Raters Course Details and Registration (Registration Form is at the very bottom of the page.) This course will provide the training required for a Certified HERS Rater to verify homes under the ENERGY STAR program. The course includes the exam which must be passed to achieve this certification. Successful completion of this course will earn the student 18 RESNET CEU's. Most ENERGY STAR training programs use a checklist by checklist, item by item approach. We found that method leaves a lot to be desired when you try to apply it in the real world. The “Thermal Enclosure System Rater Checklist” if completed from top to bottom requires you to traverse the same path up to six (6) times - we counted 538 total steps! The ARN optimized training method instead teaches you what to verify inspection by inspection rather than checklist by checklist.
When you look at a window, you are prepared to verify everything needed for that window at one time. This reduces the number of steps to 138 and this is just for one of four (4) checklists which must be completed for ENERGY STAR. Save the steps for the gym. When you are working, every step impacts your profits. Where you choose to get your training can make a significant difference in the amount of time spent on-site and at your computer. ENERGY STAR Program Requirements This module will provide an overview of the ENERGY STAR Program requirements for all participants, the Builder, the Rater and the HVAC contractor. Included is an overview of ENERGY STAR certification paths, the target HERS Index, the Benchmark Home Size and Size Adjustment Factor, and trade-off limitations. Course Introduction: ENERGY STAR Version 3 ENERGY STAR V3: Course Materials ENERGY STAR v3: Introduction ENERGY STAR v3: Introduction and Basics Quiz ENERGY STAR v3: Prescriptive or Performance
ENERGY STAR v3: Builder's Choice - Prescriptive or Performance Path Quiz ENERGY STAR v3: The Prescriptive Path ENERGY STAR v3: The Prescriptive Path Quiz ENERGY STAR v3: The Performance Path ENERGY STAR v3: The Performance Path Quiz ENERGY STAR Checklist Package and Partner Verification What are these checklists that ENERGY STAR Certification Requires? Where are they found? How does a Rater know which ones to use? Who on the project team needs to be trained or credentialed as qualified to work on an ENERGY STAR project? What credentialing responsibility does the Builder and HVAC Contractor have? Those questions and more will be answered in this module. ENERGY STAR v3 Checklists: Course Materials ENERGY STAR v3: Checklists ENERGY STAR v3: Checklists and Partner Verification Quiz Third party verification is a major component of ENERGY STAR qualified homes. This module will take you to the field and teach you what to look for when verifying for the ENERGY STAR program.
You will work through several site visits and understand how what you see in the field translates to what you record on your checklists. ENERGY STAR v3: Introduction to Verification Inspections ENERGY STAR v3 Inspections: Course Materials ENERGY STAR v3: Pre-Slab Inspection ENERGY STAR v3: Foundation and Roof Inspection ENERGY STAR v3: Pre-Drywall Inspection Introduction ENERGY STAR v3: Pre-Drywall Inspection of Walls ENERGY STAR v3: Pre-Drywall Inspection of Fenestrations ENERGY STAR v3: Pre-Drywall Inspection of Moisture Management ENERGY STAR v3: Pre-Drywall Verification of HVAC Design ENERGY STAR v3: Pre-Drywall Inspection of HVAC Systems ENERGY STAR v3: Pre-Drywall Inspection - Other Considerations ENERGY STAR v3: Construction Complete Inspection Partnering with ENERGY STAR This module includes information about ENERGY STAR Partnership benefits and how ENERGY STAR helps you grow your business. ENERGY STAR v3: Partner Resources