Now that we’re halfway through the summer your air conditioner may be showing its age. If it’s not cooling properly, there are some simple things you can check like the filter. Other issues are more serious and may require you to call a pro. Here are some common problems and what to do about them with advice from the experts at Consumer Reports and the Department of Energy. Won’t start at all. If your air conditioner won’t start, the compressor and fan controls could be worn out from the system turning on and off too frequently. If this is the case, you should call a technician to check the electrical connections.Check your thermostat to make sure it’s set properly and that it’s reading the correct temperature. On but not cooling. Your refrigerant could be low or leaking. Call a pro to repair any leaks and recharge the system. Not working like it used to. If you have a window unit, the thermostat sensor may be knocked out of position. Carefully bend the wire holding it in place to properly position it.

Check your unit’s drain to make sure it isn’t clogged. If it is, carefully pass a stiff wire through it.A clogged filter restricts airflow through the unit decreasing its efficiency and reducing the ability to effectively cool the air. If you haven’t already cleaned your filter this summer, do it now. Warm air is leaking in. Check the window seals around your unit to make sure hot air isn’t getting in or cold air seeping out. If so, reseal around your unit. Top air conditioners from our tests If your air conditioner is a goner, it’s time to get a new one. When buying a window air conditioner, make sure you get the right size air conditioner for your room. Here’s a top performer for each size we test.In our survey of 34,000 of our readers who recently installed central air conditioning, American Standard, Bryant, and Trane logged the fewest repairs. Choosing one of the more reliable brands in our survey can boost the odds that you’ll be comfortable for the rest of the summer.

—Mary H.J. Farrell (@mhjfarrell on Twitter) View and compare all Air conditioners ratings.
first ac unit My Window Air Conditioner Smells Bad!
ac unit goes out Q: I bought a new window AC at the start of summer and having been using it regularly since, but now it's starting to smell like mildew every time I turn it on, a funky odor wafting throughout my apartment.
best ac unit reviewIt's too hot not to keep it on, but I don't want to live with this smell. Can anyone recommend how to get rid of the smell? Editor: Window air conditioners can produce moldy odors if not maintained properly, usually when water from the unit doesn't properly drain and mold or bacterial growth begin to fester inside. Check out this window AC maintenance checklist for future reference and the video below showing how to clean air conditioner coils.

There's also some who use a bleach+water solution or Lysol to disinfect the system, but when in doubt, you'll want to call a HVAC serviceman to handle the cleaning and point out the cause of the odor. Leave your suggestions for Shaun in the comments - thanks! • Have a question for our community? Send us yours with a photo or two attached (questions with photos get answered first). Can I recharge my window unit air conditioner or do I have to send it to a specialist? The AC unit that I have is about 15 years old (nothing lasts forever)... and I happen to have about 20 lbs of R22 on hand... so I wrote this up. The AC isn't really leaking, but after about 15 years I have lost a couple pounds. Air conditioners do not magically lose refrigerant. If refrigerant is missing, the air-conditioner leaks; if the leak is not fixed, it will continue to leak. A window unit is almost always a bad economic choice to attempt repairs on rather than replacement; since USA-based persons DO need a license to handle refrigerants, and anyone world-wide needs specialized equipment (and one, hopes, enough training to use it correctly), the cost of service (particularly with older, very expensive refrigerants) is far above replacement, particularly when the power efficiency of a newer unit when running is factored into the equation.

The cost of having a qualified, equipped person (or becoming that person) find and repair the leak (on a unit typically not made with ease of service and repair in mind) will almost always exceed the cost of a new unit to replace it. It's a waste of money to try. Especially if you're the guy who pays for the electricity. Captain Kirk didn't beam the Freon out. First, you'll want to fix your Freon leak. After all, air conditioners are generally sealed units, with only electrical wires entering the envelope that contains freon. However, they use a lot of aluminum, as it is a superb themal conductor, and cheap. Accumulated dust in the cooling coils and fins tends to hold water, a perfect storm for aluminum corrosion. Good chance you have a pinhole in the condenser. Likely you have a foreign made pile of junko, so there is nothing in the unit designed to help you. Every inch of tubing in the unit is welded, and there are no spare parts to be had for the mechanical package.

If you have an old school solid American unit, it most likely takes the long-discontinued R12 or R22 Freon, so you are paying top dollar for old stocks. Contrary to what comic books say, a Freon accident will not turn you into Mr. Freeze. Cold is not like fire, you don't instantly feel the pain, you can expose yourself long enough to do damage before you realize it. And there you are, using third party parts of dubious quality, since no manufacturer endorses even authorized repair of the Freon containing machinery - it is not economical even if they made it easy, which is why they don't. Who pays the electricity bill? If it's you, you're paying again to run an old inefficient unit. Ten years ago I bought a solid Sears unit that did 5600 BTU and drew 5 amps. My friend just bought a private label no-brand junko unit that did 8000 BTU for 5 amps. His unit runs 1/3 less often, so he's saving about 200W or 1 KWH every 5 hours. An older unit would be even worse. This is due to Federal laws requiring ever-increasing efficiency.

Then imagine what a quality unit would do. Even if you can get 5 more years out of your old unit, the new unit will pay for itself in electricity costs alone, to say nothing of all that other stuff. So fixing an old unit is a false economy. What you need to know: You are supposed to be EPA certified to work with freon, so the following is only for educational purposes and some pertinent information may be missing. An air conditioner should be cooling the air by about 15 to 20 degrees Fahrenheit. To check that, hold a thermometer in front of the air conditioner where the air is comming out. It should be about 15 to 20 degrees cooler than the temperature of the air in the room (more specifically, 15 to 20 degrees less than the air going into the air conditioner). Window units prior to 2010 primarily use(d) R22 (also called HCFC-22) freon. R410A (also called Puron) is the standard as of 2015. A 5 ton AC unit has 10 to 20 pounds and a 3 ton AC unit has about 6 to 12 pounds of freon.

What do I mean by tons? Tons are kind of like horse power. Tons refers to the amount of ice that would be used to remove a similar amount of heat (and for window AC units, it's around 3 to 5 tons per hour). R22 systems use mineral oil for lubrication whereas R410A uses a synthetic polyolester oil. Mixing refrigerants is illegal in USA. Most window units do not have a port installed so that you can add freon. The larger copper tube leading to the compressor is the low presure side (and the smaller tube is the high pressure side). Generally, about 1 or 2 pounds of refrigerant should be enough to top off one AC unit. How do you measure that? One way is to put the canister of refrigerant on a bathroom scale and weigh it... a bathroom scale might not be perfect, but it should be pretty close. You probably won't need to add more oil. A self piercing valve (currently the price is about $2 to $5) to the low pressure copper tube. The tubing size may be 1/4", 5/16" or 3/8" so you will need to measure that first or get a "universal" piercing valve that accomodates multiple sizes.

A refrigerant refill hose (currently the price is about $10 to $30). Refrigerant: currently the price for R22 is about $260 for 10 lbs and the price will continue to climb until the stocks are depleted; or for R410A refrigerant, the price is currently about $110 for 25 lbs or you can get about 28 oz for about $70. What you need to do: Measure the temperature to see if you need refrigerant. Check the make and model of the air conditioner to find out if you need R22 or R410A. If you need R22 the cheapest option would be to replace the window unit. Measure the size of the low pressure tube and order a self piercing valve. Order the refrigerant and any necessary hoses or connectors. Attach the self piercing valve to the most convenient/accessible location along the low pressure tubing. Turn on the AC unit (max-high) and add the refrigerant while it is running (warning!!! watch out for exposed electrical wires). Don't forget the bathroom scale, to weigh the canister (before and after).