how to clean air handling unit

AIR HANDLING UNITS  |  Standard Specifications — Recirculating Fan Cabinets Fan cabinets are constructed of 18-20ga Galvanized Steel with 14-16ga internal channels and braces. Cabinets are supplied with removable access panels for serviceability of motor and blower(s). Fan cabinets can be furnished with provision for suspension or mezzanine mount applications. Standard configuration is back inlet, top horizontal discharge. Other configurations are available. Cabinets are lined with 1″ thick insulation to minimize sound and loss of temperatureStandard insulation is a non-shedding liner, secured to the internal surfaces of the fan cabinet with approved adhesive. All exposed edges of the liner are sealed. Internally Isolated Motor Blower Assembly Standard configuration is a single motor and a single blower installed on a common frame which is mounted to the cabinet with adjustable spring isolators. Multiple blowers with a common shaft and motor are available for a lower profile cabinet.
Units built to required CFM with capacity to overcome customer specified system static pressure. Standard Prefilters are 2″ or 4″ thick, 30% ASHRAE supplied in a face load Prefilter frame for ambient return air. Chilled water or DX coils can be added with or without drip pans for temperature and/or Cabinet: Painted steel, Stainless Steel Construction Configuration Discharge: Bottom Horizontal, Bottom, Top Inlet: Side, Bottom, Top [Click here for a PDF of this content.] AIR HANDLING UNITS - HYGIENE VERSION TANGRA AHU – HYG Hygiene air handling units TANGRA AHU-HYG are certified by TÜV Rheinland, in accordance with VDI 6022, VDI 3803 and DIN 1946 - teil 4 regarding hygiene norms, as well as DIN 1886, EN 13779 и EN13053 for ventilation and air conditioning systems. To download the brochure, please click "here": "Hygiene Air Handling Units TANGRA" Get Best QuoteWe are one of the widely acclaimed exporters, manufacturers, suppliers, traders and importers of Air Handling Unit.
The offered air handling unit is designed for the clearing off the dust particles from air. Our supplied air handling unit is available in multiple variants such as blow-through and draw-through. The offered air handling unit can be mounted on floor or wall. Equipped with Pre filter selection Equipped with mist eliminator Longer service abilitySelection Parameters:gas furnace ac unit Type: Floor Mount / Wall Mount / Horizontal / VerticalDesign: Blow Through / Draw ThroughFrame Work: Thermal Break / Non Thermal BreakPanel MOC: Double Skinned / Singled SkinnedBase Frame: GI Skid with Corner / ‘C’ ChannelOuter Sheet: Pre-Coated with PC / Powder CoatedInner Sheet: Plain GI / Pre-Coated / SSPanel Thick: 25 mm / 45 mmInsulation: Injected PUF @ 40±5 Kg / m3Static Pressure: 50 mm to 200 mm WGTypes of Drive: Belt Driven / Plug FanTypes of Fanhow hvac blower motor works
: Backward Curved / Forward CurvedFiltration Stage: Pre-Filter / Fine Filter / Bag Filter / HEPA FilterNo. of Damper: SA / RA / FA / PAType of Damper: Aerofoil / GI Powder CoatedTypes of Zone: Inlet Lower with bird Screen High Performance AHU with Self Cleaning Filter Get Best Quotehigh performance AHU with self cleaning filter for clean room applicationwhat is ahu with automatic filter cleaning system? cost of a 3 ton hvac unita unique and one of its kind products in air filter technology ever made. our ahu with automatic filter cleaning system will provide clean air as per specified standard, uniformly and continuously without any interruption as well as with an automatic cleaning arrangement. This will solve the various unsolved problems of pharmaceuticals & research centers in air conditioning system. This is really a revolutionary system and a miracle in technologies and shall save the immense energy.
“self-cleaning filter system” is technically upgraded and much sophisticated as compared to existing conventional systems. It is 100 % up on the available of present technologies.how does ahu with automatic filter cleaning system work for you? in our design concept, there are numbers of cylindrical filter can be fitted in ahu and remain perfectly clean without service by opening the ahu system. It rotates in slow rpm of about 27 to 30 per hour through gear motor and timing belt on their axis. The air passes through the outer peripheral of filter to inside and remaining part of all sides of filter are closed and sealed. The air passes through only outer peripherals. The dust particle remains on the outer side of peripheral of filters which rotate and come to the down side.there is a provision inside the filter to blow off filtered air by blower on precise velocities and precise pressure. On the bottom of ahu we provide a suction point, which is connected to the pulse jet dust collector .
The dust collector sucks dust from air that parted the filter. No dust particle remains in ahu and filter is continuously free from any dust particle. Thus the system remains clear and ahu remains totally clean. There is no risk of cross contamination or bacterial growth, so there is a lot of saving of power and wastage of time to stop the unit to clean up.the most positive and quality management of clean room which is unnoticed that, we are providing clean room without voc(volatile organic carbon)gases which generating in ahu due to the collection of powder from long time in ahu. features of ahu with automatic filter cleaning systemzero level of blocking of filterzero level air contaminationmaintained air quantity ratio (cfm)maintain air velocity levellow noise levellower current consumptioncreate high quality of airminimum time to maintenanceminimize the possibility of leakagereduce cost of laborminimum filter rapture possibilityminimize bacterial growthincreased confidence level Ask for PriceItem Code: AHUWe are one of the leading exporters, manufacturers, suppliers, traders and importers of AHU System.
The offered package air handling unit system is a robust construct which is used for the filtration of air particles. Our supplied package air handling unit system is commonly used in multiplex malls, research laboratories and hospitals. Anti-bacterial unit Optimal air velocity Longer service life Benefits: Our System are generally mounted on brackets hence avoiding the service floor for repairs and maintenanceEntire Clean Room setup in 24 HoursPhase wise installation without disturbing the entire unit hence also saving on capital cost and initial investments.05 micron area easily upgradable to HEPA Filter (0.3 Micron) Just changing the filter.All Filters are easily accessibleAll in a box solutionNo expertise neededAll from one source - Easy to Fit - Easy to Install - Easy to CleanEco FriendlyNo Maintenance Compact AHU System / Package AHU System Clean Room Package AHU System / Clean Room Compact AHU System Air Handling Units Compact Ask for PriceItem Code: AHUSWe are one the well-known exporters, manufacturers, suppliers, traders and importers of Air Handling Units Compact.