The 2-5 ton Rheem 13 SEER RSNM & 14 SEER RSPM, Dedicated Horizontal Package Air Conditioning units feature earth-friendly R-410A refrigerant. This platform provides you with a full line of capacities that are each AHRI-certified. Additional BenefitsThe Scroll® Compressor. All of our residential package units, regardless of efficiency level, feature the Scroll Compressor. They have fewer moving parts, and they are quieter, more efficient, and longer lasting. Durable Cabinet with Louvered Condenser Compartment. Our cabinets have a powder painted finish that protects them from the harshest weather extremes. And our louvered condenser compartment is the best in the industry for protecting the condenser coil against yard hazards and weather extremes. There is a One-piece top with a drip lip to help keep water off of the unit sides. Supply and return air openings feature a one-inch tall flange to prevent water migration into the ductwork. Access panels have “weep holes” and channels to further help manage water run-off.  
Easily accessible blower section complete with slide-out blower. Refrigerant connections are conveniently located for easy service diagnostics.Our mount helps protect the fan motor from the elements for longer life. Its design dependability helps reduce vibration and noise.Easily Accessible Control Box. Operational controls are “up front” for quick installation and easy service diagnostics.Matched Blower/Evaporator Coil Unit. The blower is responsible for the flow of air into your duct work. It has been designed to match the MultiFlex® evaporator coil and other system components for maximum efficiency and quiet operation. In addition, the coil features rifled copper tubing and enhanced fins for improved efficiency.Exterior service fittings enable a serviceman to quickly determine unit operating conditions.Supplemental Electric Heating Strips. Supplemental electric heat strips up to 20 kW are available (field or factory installed) for periods of extreme cold temperatures. Single point wiring simplifies installation.
Rugged base rails are included for improved installation and handling. RSNM (2 - 5 Ton) RSPM (2 - 5 Ton) Conditional Parts Warranty - 10 Years (1-Phase Residential -  Registration Required) Compressor Warranty - 10 Years (1-Phase Residential) Limited Parts Warranty - 1 Year (Commercial)This 50 Ton air conditioner unit includes cooling, heating, and dehumidification functionality for emergency water removal.ac unit freezing up fix Portable Air is proud to offer horizontal air conditioner units to meet any temporary climate control project needs. air conditioner and heater filtersOur entire fleet is comprised of only the most reliable, well performing units from top manufacturers such as Trane, Carrier and York.air conditioning repair in new york city
All units can be rented as individual units or as a complete “turn-key” package including complete delivery, installation, startup and required accessories. Contact one of our rental representatives today to learn more about Portable Air and the largest HVAC air conditioner rental fleet of its kind.Video overview of our Horizontal Package Units: Portable Air is a trusted source of portable package units specifically designed to provide temporary climate control solutions. Portable Air features skid-mounted package units from top manufacturers such as Trane® and Carrier®. These units have the highest standards in quality and reliability, ease of service, performance and comfort. We at Portable Air know that the equipment we offer has to operate immediately under time critical circumstances. When you need it done right, go with a brand you can count on! All package units come standard with a heavy-duty skid with forklift pockets for easy transport. Units can also be mounted to one of our trailer packages.
All trailers that we place our packages on are Heavy-Duty and DOT Approved designs with plenty of storage for package unit accessories such as flex duct and power cable. 4 Ton, 15 SEER Self-Contained Packaged Air Conditioner, Horizontal This GPC15H Packaged Air Conditioner features energy-efficient cooling and heating performance in one self-contained unit. The heavy-gauge, galvanized-steel cabinet is protected by a high-quality, UV-resistant powder-paint finish. This unit allows for ground-level or rooftop applications. Goodman has become one of the largest manufacturers of residential and light commercial air conditioning, heating, and indoor air quality products and systems by focusing on just one thing, building the most reliable and refreshingly affordable indoor comfort products in the market. Energy-efficient compressor with internal relief valve Multi-speed ECM indoor blower motor Quiet horizontal discharge All-aluminum evaporator coil Copper tube / aluminum fin condenser coil Totally enclosed, permanently lubricated condenser fan motor Fully charged system 5 kW to 20 kW electric heat kit available as a field-installed option AHRI Certified;
Heavy-gauge galvanized-steel cabinet with attractive Architectural Gray powder-paint finish Fully insulated blower compartment with convenient access panels Louvered condenser coil protection One footprint;  Horizontal Return / Supply Duct Cover Kit for Large Chassis GPC, GPH and GPG Self-Contained Units Single Point 50 Wiring Kit 14 1/8" x 24 1/8" x 14" Dia. Take-Off Collar, Return Furnace and Air Handler Configurations You likely have in your home one of two basic air delivery systems, either one which will be necessary to operate a central air conditioner: a furnace or an air handler. furnace is comprised of a heating device, gas or electric, as well as an air circulating fan. An air handler looks very much like a furnace, but has only a circulating fan without heating capability. furnace or air handler is configured one of two ways:Looking at your unit will tell you which one you have. If your furnace/ air handler is vertically
aligned, then it is up-flow or down-flow. If it is horizontally aligned, it is horizontal-flow. Depending on which configuration you have will determine which one of the two types of corresponding evaporator coils you will need for your home�s particular air installed on a platform suspended from roof or floor joists installed in a closet STANDS FOR: HEATING, VENTILATION, AIR CONDITIONING. we will define other terms you will hear in the HVAC industry to help make you a more educated consumer. 1992, the Federal Government established minimum efficiency requirements for all heating and air conditioning equipment. If your present HVACa furnace, heat pump, or air conditioning system was purchased and installed before that date, it could be highly inefficient by today'sEfficiency ratings are important to understand because installing a new unit could achieve significant energy costAnd that could save you from the higher operating expenses of
Department of Energy is a federal agency in charge of setting industry efficiency standards and monitoring the consumption of energy sources."AFUE" is a measure of a furnace's heating efficiency. stands for Annual Fuel Utilization Efficiency. The higher the AFUE%, the more efficient the product. The government's established minimum rating for furnaces is 78%. HSPF = Heat PumpIt stands for Heating Seasonal Performance Factor, orThe higher the HSPF rating, the more efficient a heat pump is atThere is no legislated minimum rating."SEER" is a measure of cooling efficiency for air conditioningSEER stands for Seasonal Energy Efficiency Ratio. SEER rating number, the more energy efficient the unit. established minimum rating for air conditioning is 10. Basic Heating And Air portion of a central air conditioning or heat pump system that moves heated or cooled air throughout a home's ductwork. In some systems, a furnace handles this function.
Heat Source: A body of air or liquid from which heat is collected. In an air source heat pump, the air outside the house is used as the heat source during the heating portion of a heat pump or central air conditioning system that is located in the house and functions as the heat transfer point for warming or The portion of a heat pump or central air conditioning system that is located outside the home and functions as a heat transfer point for collecting heat from or dispelling heat to the outside air. year 'round heating and air conditioning system that has all the components completely encased in one unit outside the home. heat pump or central air conditioning system with components located both inside and outside of a building -- the most common types installed in The auxiliary or emergency heat provided at temperatures below a heatIt is usually electrical resistance heat. as the heater package. But supplemental heat can also be gas or oil -
Zone: A zone is the area that one thermostat is controlling. For example: A two story house with a thermostat on each floor has two zones, one for each floor. Technical Heating And Air Ton: Heat pumps and air conditioners are generally sized in tons. Typical sizes for single family residences are between two and five tons. Each ton equals 12,000It is important to note that actual capacity is not constant and will change based on outdoor or indoor temperatures. capacity rating of air conditioners and heat pumps is based on performance at the ARI standard temperature levels of 95 F outside, 80 F inside. outdoor temperature -- usually between 30�F to 45�F -- at which a heat pump's output exactly equals the heating needs of the house. balance point, supplementary electric resistance heat is needed to During the heating cycle of a heat pump, frost may build up on the outdoorTo remove the frost and maintain efficiency, the system will
This usually only takes a few minutes, then the system automatically switches back to heating. It is normal to see steam rising from the outdoor unit when this happens. British Thermal Unit (BTU): The amount of heat required to raise the temperature of one pound of water (about one pint) by one degree Fahrenheit. (COP): A ratio calculated by dividing the total heating capacity provided by the heat pump, including circulating fan heat but excluding supplementary resistance heat (Btu's per hour), by the total electrical input (watts) x 3.412. (See Heating Seasonal Performance A ratio calculated by dividing the cooling capacity in Btu's per hour (Btuh) by the power input in watts at a given set of rating conditions, expressed in Btuh per watt (Btuh/watt). (See Seasonal Energy Efficiency Ratio, Watt (W): A Watt is a unit of electricity. kilowatt equals 1,000 Watts. A kilowatt hour (kWh) is the amount of kilowatts of electricity used in one hour of operation of any equipment.