gas air handling units

We represent a variety of the industry’s top manufacturers all featuring quality products at competitive prices. Both Air-Side Equipment and our partners offer you easily available product information and after-the-fact technical support on all our equipment. Centrifugal fans, power ventilators, wall fans, utility sets, kitchen hoods. Fire, smoke, manual, and industrial dampers, Louvers .and Laboratory exhaust fans. Indoor air handling units. Gas fired make-up air units. Low profile fan coil units. Replacement DX and water coils. Grilles, Registers, Diffusers & Terminal Units (VAV Boxes) and Sound attenuators. Architectural access doors/Roof hatches and Smoke vents Electric duct, baseboard, wall, and unit heaters. Gas flue exhaust fans and control systems Single & double wall round, oval, and specialty duct Vehicle Exhaust, Welding, And Dust Collection Fabric Air Dispersion Systems Air Filtration Products (Complete Line), Pre-Filters Pleated, Glass & Media, Final Med. & High Efficiency Filters, Carbon Filters, HEPA (Absolute) Filters, Filter Framing Systems, Side-Access Filter Housings, Self-Contained Filtration Systems, Roll Filters, Gas Turbine Filters, Mist Removal & Moisture Separation, Metal Panel Filters, Source Capture Collection Systems, Bag-In / Bag-Out Filtration Housings, Industrial Air Filters & Equipment, Laminar Flow Clean Room Filters, Nuclear HEPA Filters & Containment

, HEPA / ULPA Filters & Equipment Bag-In / Bag-Out Filtration Containment Systems , HEPA (Absolute) Filter Systems, Containment Systems, Biological Filter Systems, Bubble Tight Biological Damper Systems, Nuclear HEPA Filters & Containment Spin Collar Fittings And Round Access Doors, Flex Duct And Acoustical Flex Duct Positive pressure boiler flue, type ‘B’ vent, grease duct Lab/Fume hood controls and hospital isolation room monitors Air Curtains and Fly Fans Residential Fans, Residential Hoods & Heaters Exterior Wall Cap, Exhaust Vent & Fan for Dryer & Kitchen Ventilation. Access doors, air mixers, air blenders, security grilles Operating room / Clean room air distribution systems Punkah air distribution, nozzle air distribution, louvers, factory ventilation outlet, recessed grille station exhaust systems, architectural and mechanical access door. Variable frequency Drives, Motor Starters UV-C Light Fixtures and replacement bulbs

HDPE Direct Burial Underground Duct THE PREMIER PROVIDER OF INDOOR AIR QUALITY SOLUTIONS IN THE WORLD: We specialize in Total Air Purification and Effective Removal of Diesel Exhaust Fumes. > Comfort units / Fan coil units > Air handling units > Autonomous (Self-contained air conditioning units) > Swimming pool deshumidification > Precision air conditioning > Ventilation & extraction fans > Domestic water solutions // terms and conditions of sale
ac window unit repair Multi-bloc air handling units
ac dc power supplies uk Available in 10 sizes.
miller ac unit not working Two types of front section available to accommodate means of transport (in overland or maritime container) and site constraints.

Air flow rates of 50,000 m³/h to 130,000 m³/h Air handling unit designed for large volumes of air (50,000 m³/h to 130,000 m³/h) at pressures reaching 2,600 Pa and even 3,600 Pa. Designed in particular for industrial facilities (processes, cleanrooms, makeup air) or for precise air handling control in commercial spaces (precise comfort) in order to meet mixing, filtration, heating, cooling, dehumidification, humidification, ventilation, recovery and sound attenuation needs. Available as a horizontal unit for indoor installation or outdoor installation with canopy and protective accessories. Free-standing design, double-skin construction with 50 mm mineral wool insulation, modular Attractive look, painted, with access doors as standard External surface made of galvanised steel with RAL 7024 (graphite grey) finish Boxes assembled to ensure smooth internal and external walls All the filters are in international dimensions and fit inside frames. They are inserted and removed from the front via an access door.

If front access is not possible, only the prefilters (95% gravimetric) may be inserted on runners through the side The coils may be one-piece (along the entire width of the unit) or made of two offset pieces in the direction of the air flow. In the latter case, one of the coils may be tilted. If so, it should only be tilted along half the width of the unit. Copper, steel or stainless steel tubes. Fins available in aluminium, coated aluminium or copper Gas burner with shutter, face plate, electrical panel and fittings, technical compartment, direct combustion in air stream (no exchanger) and fresh air only operation The selection may be optimised with two or three solutions: one or two fans, two or three impeller diameters, four possible discharge directions, frame, motor bracket, belt idler, protective housing, flexible sleeves, anti-vibration mounts Adiabatic cell or steam humidifier, air washers (90% efficiency) Standard or sealed dampers Options: door contact, proximity switch, keyed lock, etc.

Sound attenuator of various lengths placed upstream or downstream of ventilation section Usually delivered as factory-assembled boxes. May also be delivered flat-packed for on-site assembly with CIAT's assistance. Designed in accordance with EN 13053 and EN 1886: class B casing air leakage, 2600 Pa as standard (-1200 Pa ; +1400Pa) and 3600 Pa with reinforced construction (-1200 Pa ; +2400 Pa), T2 thermal transmittance as standard, TB2 thermal bridging, 1A to 2A mechanical strength, F9 filter bypass leakage. Meets the mechanical safety requirement for fans. Manufactured in ISO 9001 certified facilities Complete range with a wide spectrum of flow ranges and many options, highly robust mechanical system, free-standing design, attractive look Two geometries, including one which allows the unit to be placed inside a container Coated, galvanised steel double-skin panels Smooth internal air handling tunnel (cleanrooms) Operation of heat exchangers optimised by extensive experience in their manufacturing