central air unit froze up

The requested URL /discuss/duboard.php?az=view_all&address=105x5356678 was not found on this server.Sometimes you may notice that your air conditioner freezes up after some time of operation. When this happens, the cool air will not be discharged properly and eventually a huge block of ice may built up on the evaporator coil. You will notice that there is less airflow coming from the air ventilation as ice began to clog the air movement. More condensation can be seen at the drain pan. At the same time, the room is no longer cool. This means that it is time to investigate the causes of this problem. Here are some possible causes. When air flow or air circulation from the unit to the room and vice versa is restricted, the exhange of thermal energy between the air conditioner and the room is restricted. As a result, most of the cool air continues to stay around the evaporator coil and fins causing the temperature around them to drop. As a result, ice is formed and gradually more ice began to built up and eventually causes the air conditioner freezes up.
Air Filters at the return air of the equipment must be serviced regularly by taking them down and wash with water and soap. These filters are used to trap dust and other bigger contaminants from going into the evaporator fins. Hence, cleaning them at least one or twice a month is highly recommended. In many cases, users will not even clean them once a year until this problem begin to surface.how long to ac units last in floridaEvaporator coil and fins that are located after the air filters can also be clogged up due to dirty filters. ac unit outside freezing upIn this case, you will need to clean them by using a spray type coil cleaner. carrier ac unit warranty registrationThe other alternative is to get the technicians to come and take down the entire evaporator for cleaning.
This will be more costly. Therefore, regular maintenance of the evaporator coil and air filters will go a long way in ensuring that your air conditioner continues to function properly.Fan or blower at the evaporator unit may not be functioning. When the unit is on, check that there is air flow coming out of the equipment. Otherwise, the fan may be damaged. In this case, the fan motor may have burnt or some loose connections may have occurred. Get a technician to check if this is the case.Check that there is no blockage of air around the evaporator by ensuring that things are not placed too near to the evaporator.One other step you can do is to check the set temperature of the air conditioner. Make sure that it is not set lower than 70 °F. When the refrigerant in the system is low due to leakage over time, there will be a decrease in the saturation point temperature of the system. When this happens, it will take a lower temperature for all the refrigerant liquid that has been compressed by the compressor to become vapor in the evaporator.
This means that the operating temperature of the cooling coils has now dropped compared to the original design. This lower temperature will cause moisture collected from the air to quickly becomes ice on the evaporator when the temperature goes below below 32 °F.These moisture that is supposed be cooled to a level which becomes water and drips to the condensate drainage pan is now stuck at the evaporator coils and fins forming ice around them. When this continues on, eventually a block of ice is formed on it. When you see the ice being formed on the evaporator, off the unit and wait for the ice to melt. It could take a few hours for all the ice to melt. A faster way is to on the air conditioner but using Fan mode. That means, only the fan is operating but the compressor is off. This will reduce the melting time of the ice but you will need to be around to monitor it as water may overflow and cause damage to your furniture or electrical items.A low refrigerant problem can only be solved by a qualified HVAC technician as additional refrigerant will have to be added to the system.
Another possible cause is when you are operating your air conditioner when the outdoor temperature outside the house is low. When this happens, try to run the air conditioner using fan mode or simply use the outside air to ventilate your room. Back To Air Conditioner Freezes Up Home pageYou may have a tripped circuit breaker. Recommended Action: Check your home circuit breaker box and reset Your thermostat/control may be off or set incorrectly. Recommended Action: Check to make sure your thermostat/control is on and set to cool. Reset to your desired temperature. Your indoor unit is running but the outdoor unit is not. Recommended Action: Air coming through your vent will be warm. temperature setting on thermostat/control. If no change, contact yourIn the meantime, try turning off your thermostat/control for 1 to 3 hours to see if it will reset itself. Your gas could be turned off. Recommended Action: Check gas valve at gas company meter, check
shutoff valve at furnace and check for other shutoff valves. the gas company to have gas valve turned on or contact your local Trane Your system could be turned off or your unit unplugged. Recommended Action: Check your thermostat and heating unit to assure that they are both plugged in. Refer to your use and care guide or contact your local Trane Your thermostat may be off or set incorrectly. Recommended Action: Make sure your thermostat is on and set to heat. If thermostat is on, reset thermostat to your desired temperature. You may have a tripped circuit breaker. You may have dirty filters. Recommended Action: Check the filters in each of your system’sClean or replace filters as recommended in your use andIf problem persists, please contact your local Trane Your system may have frozen up due to a dirty coil. Recommended Action: Check for signs of water below unit and cold exterior surface of indoor coil enclosure.
Contact your local TraneIn the meantime, try turning your thermostat off for 1 to 3 hours to see if it will defrost. If your system is reaching its set point, is it working correctly? Have your local temperatures been extreme lately? Recommended Action: Check the following: Is your system cyclingIs your thermostat reaching its set value? Do you have any new appliances (e.g., a hot tub or pool heater) that use lots ofHave you checked to see if your local utility company had aIf your system is not reaching its set point, please contact your local Trane Comfort Specialist. Your system could be trying to reach a set point that is too extreme. Recommended Action: Check the set point on your thermostat. very low (in summer months) or very high (in winter months)? If that doesn’t work, please contact your The overflow switch is probably not working Recommended Action: Turn off your system and contact your local Check any of the above troubleshooting issues for help.