air handling unit german

The requirements on a ventilation system are not always the same. In many applications, all that is required is a straightforward exchange of air, whereas in other applications the requirements can be very exacting with regard to temperature, humidity and purity of the air. Rosenberg air handling units in the Airbox series have a modular design and can be individually configured. In this way, the appropriate solution can be assembled using a kind of modular principle for each application in a quick and straightforward procedure. Both, in the high-tech area and for classic building technology, air handling units from Rosenberg deliver clean air at the right tempered room climate. Weather-proof and explosion-proof designs are possible, as well as TÜV certified hygiene variants. The units consist of a framework structure with double-skinned panels that have acoustic and thermal insulating properties. The individual modules for the filter, fan, heater, cooler, heat recovery, acoustic insulation as well as the frame materials, are assembled flexibly according to the customers‘ requirements.

The F40 series is produced in a frameless design. The panels are screwed together from the outside so that the devices are smooth internal surfaces and are hence hygienically safe. The air handling units Airbox A20, S40, S60, T60 are equipped with a framework construction made from aluminium or galvanised, rolled steel profiles and aluminium cast corner connectors or plastic corner connectors. In the case of the Airbox A20, the double-skinned panels are insulated with non-combustible, sound and thermal insulating mineral wool. The Airbox S40, S60 and T60 air handling units are also filled with non-combustible, sound and heat insulating rock wool insulation. In addition to galvanised steel panels and the framework construction, it is also possible to select coated steel, aluminium and stainless steel versions in our range. For modules with smaller dimensions, the base frame is manufactured in various heights (100, 300, 500 mm) using galvanised, folded steel sheet. Larger modules have a welded base frame (primed or galvanised).

3 mm aluminium profile 1,5 mm galvanised steelor stainless steel 1,5 mm galvanised steel 1,5 mm aluminiumand thermally decoupled The main factors which are important for the energy efficiency of an air handling unit are the air velocity in the profile unit face as well as the electric power consumption of the fan which is dependent on the air volume and pressure increase.
air conditioning single unitIn a combined air handling unit with heat recovery (HRU), the efficiency and pressure loss of the heat recovery must also be taken into account.
ac units for large windows We work in accordance with the statutory requirements of the German Energy Saving Ordnance (EnEV), as well as the requirements of the German AHU Manufactures Association (RLT) when selecting the parameters for air velocity, the electrical power consumption of the fans and the efficiency of heat recovery.
home central air conditioner how it works

The criteria of the RLT energy efficiency label correspond to the standard DIN EN 13053 A1 (2011). This standard defines nine air velocity classes from V1 to V9, six heat recovery classes from H1 to H6 as well as six classes for the power consumption of fans from P1 to P6. The specific power consumption of a fan (SFP), installed in the air handling unit, is calculated as defined by the current DIN EN 13779. Air velocity class without thermal air treatment Air velocity class with air heating and / or heat recovery Air velocity class with additional functions Electric power consumption class Heat recovery classes (4,000 - 6,000 hours per year) > 1,6 to 1,8 > 1,8 to 2,0 > 2,0 to 2,2 > 2,2 to 2,5 > 2,5 to 2,8 > 2,8 to 3,2 > 3,2 to 3,6 The accuracy of the data output by our AHU selection software is regularly checked and certified by TÜV Süd, on behalf of the RLT association. For more information about the RLT energy efficiency label, refer to the AHU guideline 01 from the German AHU Manufactures Association (RLT).

Test certificate of energy efficiency labelFile format: .pdfFilesize: 632.69 kBCompact Air Handling Units Series You hear them hardly, but you feel them. Flat air handling units are specially designed for installation in false ceilings. The devices are characterized by extreme... more ... To control the ventilation or air handling unit's different actual states, like supply, room or extract air temperature, depending on the version,... more ...AL-KO ATEASY and ATFLEXWhether as a central ventilation unit for public buildings, as an air handling unit for offices and hotels or for air handling in production and as an AHU for process air – AL-KO ATEASY and AL-KO ATFLEX are the right choice. AL-KO has been active as a reliable partner in the field of building services equipment with air conditioning and ventilation technology for decades. As a producer of air handling units and an exporter of central ventilation units, AL-KO provides this experience in the ATEASY and ATFLEX model series.

These are available as an AHU with ATEX design for pharmaceutical, chemical and medical applications such as operating theatres. ATEASY and ATFLEX have been successfully tested in accordance with VDI 6022, RU 01 and DIN 1946. They are available both as modular, customised air conditioning units and as large-scale air handling units. The ATEASY and ATFLEX are perfect for providing air conditioning and ventilation for hotels, exhibition halls, office buildings, hospitals and on ships. ATFLEX creates the right process air in the automotive industry, in the cleanroom, in production, in the hospital. WK-com in N / S / H ATEX Highest Safety even in explosive Atmospher RLT-units placed in explosive atmosphere or delivering explosive air are subject to special requirements whic...more ... WK-com N / S / H V4A acid- and alkali-resistant, for offshore use as well. Some working environments for air handling units place much greater demands on surfaces that cannot be...more ...

WK-com N / S / H Weatherproof WK-com N / S / H Weatherproof up to 110 mm wall thickness, combined up to 200,000 m³/h. Our weatherproof air handling units of the series WK-com belong to the most silent...more ... Swimming Pool Air Handling Units Challenges in the Swimming Pool Area Standard air handling units are overwhelmed with the special requirements in the swimming pool and spa are. Here the feeling of comfort and h...more ... Hygienic Air Handling Units The highest demands are placed on the hygienically perfect construction of the housing of hygienic units WK-com H Hygiene. Additionally jointed, absolutely sm... Refrigeration Air Handling Units In the production of refrigeration three different methods are used in principle.In practice, the procedures are often used in combination. Direct Fired Air Handling Units So Convenient, so Effective... One of the most economic systems for air-conditioning is heating the supply air by an oil or gas fired heat exchanger.