air handling unit example

Air handling unit (AHU) repair and refurbishment VES Specialist Site Services can refurbish any model of existing air handling or packaged air conditioning equipment, including those supplied by other manufacturers. The refurbishment of existing air handling and packaged air conditioning equipment is a practical alternative to replacing with new. Those with experience of on-site refurbishment quickly realise the benefits:Cost effectiveness Typically, the refurbishment cost of existing equipment is 35-50% of the cost of new, this excludes the removal and re-installation costs. New components can often be flat packed to further save crane and road closure costs. If budgets are tight, quotes can be provided to give an itemised list, so works can be limited to essential items only.Less disruption, more flexibility Works can be scheduled so as not to interfere with a client's business or their neighbours. VES can even carry out works overnight or at weekends.

Refurbishment is often a quicker option from start to finish than replacement. It also gives the choice of separating the necessary works and completing at different times for greater flexibility. For instance, a gas burner can be replaced one weekend, casework and other components on another. A controls upgrade that can integrate with BMS could follow, with other equipment on site. This could include adding a cooling coil, heat recovery, higher grade filtration or upgrading fan performance. Increased efficiency means running costs can be improved by a considerable margin. What can be refurbished? A lot can be achieved with equipment in poor condition. The example below shows the in-depth AHU refurbishment process that VES offers. If properly maintained, Specialist Site Services can give another 15 years working life to existing equipment. Roof panels are often the main cause of deterioration of an expensive AHU. Depending on budget, they can be treated or replaced.

Specialist Site Services can replace damaged top panels and add an external covering. For large roofs, particularly those with irregular shapes, Specialist Site Services offer a polybutyl seamless roof, with a 10 year guarantee. This is particularly useful on units with high suction pressures that tend to pull water through roof sections, causing rusting. Heating and cooling coils For units with restricted access, replacement coils can be provided in sections which are then joined on site, replacing valves and actuators as required. Coils can also be flat packed to suit further restricted access situations. Specialist Site Services can repair or replace any make or model of gas heater in AHUs. DampersJammed dampers are one of the biggest causes of incorrect AHU operation and can easily be repaired or replaced. FiltersMany older units have poorly fitting filters allowing bypass of unfiltered air. Specialist Site Services can replace filter frames to prevent this and often fit higher grade filters as required.

All fan types can be repaired or replaced. Also, fans can often be replaced with the latest energy efficient direct drive fans, as below, and inverter controlled. Replacing old forward curved fans with new plug fans can use 15-20% less energy. Regular maintenance is the most effective way of making energy savings and extending the life of air handling equipment.
ac unit houstonA maintenance agreement with VES will keep your AHUs in peak condition all year round - contact us for more details.
ac unit brand comparison Refurbishing Packaged AC Units
the first ac unit was invented by who Restrictive Site Access Solutions Site Installation Assistance for Contractors Post Installation Checks for HVAC Electrical Controls

Specialist Spares and Maintenance Frozen Coil Repairs and Temporary Ducted Heating News and Case StudiesPlease enter your emailaddress and we will send you a link to change your password. The OXYCOM R&D department is well equipped to perform OXYCELL® and OXYVAP® performance simulations for applications under specific climate conditions. Performance data reports are available upon request. Please contact us with your specific needs or click on the link for a Sample Page of a Performance Data Report. Based upon our in-house experience integrating the OXYCELL® and the OXYVAP® into a wide variety of indoor climate control systems, OXYCOM actively supports its customers in the development of application concepts as illustrated by the examples below. Design study OXYCELL® based ALL SEASON ventilation system Dimensions (H x L x W) 950 mm x 3 300 mm x 2 030 mm (37.4" x 129.9" x 79.9") 9 000 m3/h (5 297 CFM) Energy efficient indirect evaporative cooling up to 80% reduction in energy consumption

OXYCELL® based hybrid air handling unit Air handling unit combining OXYCELL® technology, conventional mechanical and direct evaporative technology to provide set-point cooling in the most energy efficient manner, achieving a reduction in energy consumption of 50-60% versus conventional mechanical cooling systems. The supply air capacity is 850 m3/h (500 CFM). De-central OXYVAP® based direct evaporative cooler 669 mm x 327 mm x 684 mm (26.3" x 12.9" x 26.9") 2 250 m3/h (1 324 CFM) 60 Pa (0.24 inch WC) 3.6 kW (12.4 kBTU/h) OXYVAP® based direct evaporative cooler OXYCOM co-developed OXYVAP® based compact “In Roof” Direct Evaporative Cooler This product has won the Australian Good Design Award for 2015 in the Hardware and Building category. To read more, click here 750 mm x 1 424 mm x 550 mm (29.5" x 56.1" x 21.7") 8 600 m3/h (5 062 CFM) 11.5 kW (39.1 kBTU/h) OXYCELL® HR based heat recovery window ventilation unit