Crosley Through the Wall Air ConditionersTo-the-wall style HVAC systems engineered for durability in non-hazardous applications Specific Systems' AirPak™ wall-mounted HVAC units are proven to stand up to harsh conditions of industrial environments, in applications where commercial units fail or a greater cooling capacity is required. Built to demanding industrial specifications Innovative two-stage dual refrigeration circuit provides 50% redundancy on all units Available corrosion resistant coatings and many other options Manufactured using 16-gauge galvanized steel Powdercoated for extra corrosion resistance Available 304 or 316 stainless steel Available aluminum for weight saving applications AirPak™ units provide consistent airflow into the conditioned space Units ten tons and up utilize dual evaporator blower assemblies Two backwardly-inclined blowers run concurrently Condenser fans are impeller type, with dual condenser fans on the APK 150, APK 180, and APK 240

Evaporator and Condenser Coils Standard coils are constructed from heavy-weight rifled copper tubes mechanically bonded to aluminum fins Evaporator and condenser coils are interlaced, containing two completely separate refrigeration circuits Highly corrosion resistant copper fin/copper tube coils are available as an option. Corrosion resistant coatings are also available as options Two hermetically-sealed scroll compressors Crankcase heaters are provided as a standard feature to further extend the life of compressors Precisely loomed and labeled electrical connections for ease of identification during maintenance or installation. Electrical panels are UL recognized under standard 508A and are CSA approved. Freezestats are standard on all AirPak units Unit mounted circuit breakers are available If the unit is designed to blow into existing ductwork, AirPak units can be engineered with ductmate flanges, vertical discharge blowers, and even plenums sized to meet the specifications of your application.

This is recommended on units 10 tons and greater At Specific Systems, we take your safety seriously. That's why we go through the painstaking process of third-party certifications on our systems. If you aren't seeing these logos from your HVAC vendor, are you certain that the system you are buying is safe? Looking for our ISO 9001 Certificate? What does "Explosion Proof" mean? What size HVAC unit do I need? Do I need purge and pressurization? Which refrigerant do I need? Do you build fully custom HVAC? At Specific Systems, we manufacture HVAC specifically designed for the modular building industry. Our industrial systems can be used on any of the building/enclosure types below, and fit just as well on static structures as they do on modular buildings. Let us help you get the correct HVAC system for application. Have you checked out our line of UL Listed Class 1 Division 2 rated enclosure coolers? Single Split System - Wall Mounted Air Conditioner - Low Ambient

Panasonic’s Ductless Split Air Conditioner products offer wide versatility in solving your cooling for a single.
air handling unit sizeThe Indoor unit(evaporator) is mounted inside the room, enclosed in a handsome space saving cabinet.
best air handling unitsIt is connected to the outdoor unit(condenser) via refrigerant lines & inter-unit wiring through a 3-1/2” opening in the wall.
ac unit fan outside not runningSince no ductwork is required, installation is simple, fast & efficient. The indoor unit has been uniquely designed to provide Whisper Quiet operation while delivering comfort throughout the room(s). Panasonic Ductless Split Systems bring together sleek styling in wall, duct or ceiling mounted systems, with whisper quiet operations, quality & reliability you can count on.

Microprocessor control ensures that the temperature and humidity levels in the room are always comfortable. Panasonic’s infrared Remote Control with and easy to read LCD Display, gives the user the capability to adjust & set: temperature, sweep (louver control), fan speeds, timer and more, for complete automatic operation. Details of previous warnings are stored and can be verified on the liquid crystal display. This makes it easier to diagnose malfunctions, greatly reducing service labor. By coupling compressor and fan operation, intermittent operation can be precisely controlled according to room temperature, so that air is efficiently dehumidified. 3 Fan Speeds and Automatic Fan Operation Convenient microprocessor control automatically adjusts fan speed to High, Medium or Low. According to room temperature to maintain a comfortable airflow throughout the room. The air sweep function moves the louver up and down in the air outlet, directing air in a “sweeping” motion around the room and providing comfort in every corner.

Louver can be manually set to the desired angle by remote control. 24-hour Clock with ON/OFF Program Timer The remote control unit allows you to set a wide variety of timer-based operations. Such functions include automatic ON/OFF with a timer setting, same time ON/OFF every day, ON timer, OFF timer and Combination timer. Weekly Timer (CZ-ESWC2), System Controller (CZ-64ESMC1U) Filter Sign / Automatic Restart Function after Power Failure Filter sign informs you when filter maintenance is necessary.25,000 : T-1series, U-1series / 150 hrs: K-1series Automatic Restart Function after Power Failure. This feature allows the system to automatically resume operation at its preset program, after power is restored from a power failure. Electric Refrigerant Control Valve The circulation volume of the refrigerant is controlled by a pulse type electric control valve. In order to attain optimum efficiency, when the power is switched ON, the opening degree of the electric control valve is controlled between 90 and 480 steps.