History of Fuji Electric Fuji Electric by the Numbers Food and Beverage Distribution Stock and Bond Information Home > Products & Solutions > Data Center Fuji Electric Low PUE Data Center - To achieve PUE 1.2X - Fuji Electric green data centers 1.We are helping to reduce the impact on the environment by using high-efficiency equipment for energy-saving electric power usage and air conditioning, and by using visualization to propose energy optimization. 2.We have an abundant line-up of solutions for constructing your green data center. 3.We offer a one-stop solution from design through construction. Fuji Products for Data Center Applicable to all types of data centers: modular type Modular Data Center (Basic configuration) ■Server block basic module80 server racks of storage, Server load: 400kW(sever unit average load: 5kW)Smallest unit: 10 server racksRobust seismic performance, up to 1000 gal ■Indirect outside air conditioning unitNo concern about dust such as PM2.5, SOX or NOXYear-round operation possibleUtilizes high-insulation housing

■UPS block500kVA UPS, high efficiency of 96.5%Standby redundancy operation with the common UPS building Example of application to a container type data center Based on the container enclosure, the hardware required for the data center is assembled as one package.
central ac units costs ■Server container (1 to 8 racks of storage)Sever average load: 12.5kW
how to hook up a outside ac unit ■Air conditioner : 4 unitsF-COOL NEO cooling capacity: 25kW
best value home ac units Example of application to a building type data center Example of partitioning part of the floor, in a building application ■Compatible with various types of floors ■Can be expanded in phases with short delivery time High efficiency Large capacity UPS7000HX-T4

Adopting RB-IGBT, achieve high efficiency, 96.5% Footprint is 35% reduced by reducing number of parts and minimizing the parts. Unit Capacity is 500kVA (PF=0.9, 450kW).8 units can be placed in parallel at the maximum and maximum capacity will be 4000kVA. Indirect outside air conditioning unit F-COOL NEO Energy-saving cooling method using outside air indirectly Water supply not required for cooling water or vaporization Necessary infrastructure is only electric power Utilization of outside air with hybrid system- Annual rated cooling power of 25 kW and 40 kW- Copes with high-humidity environments Indirect air usage methodShuts out causes of corrosion from the outdoors Utilization of outside air throughout the year EEC's Data Center & Telecom Insight Blog There are a few important questions that facility and data center managers need to ask themselves to make sure they are on the right track in terms of timely and proper computer room air conditioning (CRAC) equipment maintenance;

these include: What maintenance needs to be done on the equipment? Preventive data center maintenance is the best approach a company can take to limit the amount of downtime on equipment in critical environments. Within the CRAC system the most common failures tend to be high temperature or high head failures - both of which can be prevented by changing air filters frequently as well as by power washing the condenser to maximizer air flow and to maintain the operation of the unit. , "Best practices for maintaining a data center CRAC unit". This article reviews several best practices that are important for maintaining your data center CRAC unit. Here are some of the items it covers: Cooling is too critical to leave to chance Fear of intentional cooling shutdown What CRAC unit maintenance should entail Taking care of mechanical items The importance of refrigerant levels, electrical testing Making time for external maintenance Be sure to take a look at the article, it offers some great information in regards to maintaining your Computer Room Air Conditioning units.

And don't forget - performing maintenance can help you save energyPerforming maintenance can also help equipment run more efficiently, which in turn helps with the longevity of the equipment, but more importantly saves money by reducing the amount of energy the equipment uses. Scopes of work to help equipment run more efficiently should include regular checks of the quality of fluids, frequently changing air filters, and power washing condenser coils to name a few. Checking fluids is essential because contaminants can result in diminished performance. Changing filters frequently is important because it will maximize the airflow in the equipment. One of the most important maintenance checks on CRAC equipment is regularly cleaning the condenser coils. Condensers are known to draw in dirt, pollen, and other debris that restricts airflow and reduces efficiencies. According to the Consortium of Energy Efficiency, facilities in which proper computer room air conditioning preventive maintenance is completed will use approximately 15% to 20% less energy than those where systems are allowed to deteriorate.

With the high cost of energy it is crucial to maintain the equipment in a data center in order to take advantage of efficiencies and save money. Companies should work with their maintenance provider to develop a scope of work - with the exorbitant cost of downtime, a strong preventive maintenance program is not an option - it's a must! data center energy management, data center preventive maintenance Contact us today for a data center assessmentSTULZ is the world's leading solution provider of energy efficient temperature and humidity management technology, specifically for mission critical applications. Find your local contact in the USA and Canada Customer focus, entrepreneurial spirit, and technological expertise Need for individualized requirements in modern data center Comprehensive service solutions to maximize efficiency and reliability STULZ USA – Air conditioning solutions you can rely on for dependable applicationsBacked by over 40 years of experience, STULZ is the foremost pioneer in the field of air conditioning solutions for dependable applications and data centers.

STULZ precision air conditioning equipment is developed and manufactured in the USA, to the very highest standards of quality, and in line with exceptionally stringent testing criteria. We are specialists in our field and are equipped with a level of technical expertise in data centers that stretches far beyond simply our core business. The STULZ product range includes:Traditional Room Cooling using Air Conditioners (CRAC) and Air Handlers (CRAH)Outdoor Mounted Air HandlersModular / Containerized CoolingRow Based CoolingCeiling Mounted CoolingEC Fan Retrofit & CRAH ReplacementUltrasonic HumidifiersDesiccant Dehumidifiers for Industrial and Remediation ApplicationsCustom SolutionsTogether with its various sizes, extensive additional options, and modularity, STULZ boasts a product range that is unique in the world and can make optimum air conditioning a reality for practically every data center project. At home all over the world As a company with locations across the globe, we have what it takes to provide data center operators, planners, and companies working in the highly-dynamic world of information technology (ITC and IT), with professional advice whenever they require it.