ac unit wire colors

Thermostat Wire Color Codes Conventional heating, air conditioning and heat pump thermostat wiring labels, wire color codes and the corresponding function description: 24 Volt Hot for Heating 24 Volt Hot for Cooling Energizes First Stage Heat Energizes Second Stage Heat Heat PumpReversing ValveEnergized In Cooling Heat Pump Reversing ValveEnergized In Heating 24 Volt Neutral(Common) leg *     Found in some Carrier furnaces **    The brown is often the first choice to use for the 24 volt common leg but white, black and blue are also used. Tip:All of this goes out the window if the person before you didn't know or care to use the accepted color codes. Sometimes it is simpler to take down the existing wiring and re-terminate using the accepted color codes than it would be to map a "creative" wiring scheme.Be Sure To See My Low Priced Thermostat Store (Lowest On The Web) How to wire a thermostat. To wire a thermostat, you must first be aware of the type of system that you have in your home.
A large majority of homes today have an HVAC system containing a Furnace (Oil, Gas or Electric) and An A/C Unit. The thermostat wiring on these systems can have very similar wiring properties. But what if you have a system that's a little different like a Heat Pump System, Then your thermostat is going to be wired a little different as well. First and foremost when you go to wire a thermostat, if you have any doubt of the type of HVAC system you have and are uncomfortable with wiring, then I highly recommend using a qualified HVAC service technician to complete your task. This could save you a lot of unnecessary expenses in the long run. Now the thermostat circuits I will be covering will consist of the two scenarios I mentioned above. But an important issue here is that the diagrams and wiring color codes are going to be the most common standardize method. Always keep in mind that who ever wired your thermostat may not have followed these procedures and your color codes will not match the following examples.
You will have to determine this before you start disconnecting any of your thermostat wiring. I would highly recommend that you write down what color wire is going to which terminal. This way if your color codes don't match the normal code as the chart below indicates, you can still get a good idea of which wire should go where on your new thermostat. If your changing your old style thermostat to a programmable type, then most HVAC systems are compatible and will work just fine with a programmable unit. But in the case of a Heat Pump system, You'll really have to do some research to verify that the programmable thermostat will work. Heat Pump systems work entirely different from standard HVAC systems and require more circuits. While there isn't an official standard for thermostat circuit wiring colors, there is a general pattern. Your best bet is to see the manufacturer's documentation (both thermostat and HVAC). If you only have 4 wires they are typically (Red, Yellow, Green & Black).
If you have (Blue, White & Blue stripe, Orange, White & Orange stripe, and possibly Green & Brown pairs as well) coming out of the wall then it is probably phone or networking wire and it isn't good because it is too thin for the current. size central ac unit calculatorIf there is a short then the current through the tiny wires could cause a fire (Thermostat wires are usually #18 gauge.) heat pump air conditioning package unitsThese colors are not standard for thermostats.hide ac unit inside If you need an inexpensive meter to work with thermostat wiring see M300 We also have meters that can display thermocouple temperature Process Control Meters (Single stage heating and cooling using gas, electric or oil heat) This is often referred to as a 1H/1C conventional thermostat
The thermostat is a set of contacts where G, W and Y are connected to R based on the following rules. If there is a call for cool, R is connected to Y (compressor). In air conditioning mode the thermostat controls the fan, so G (Fan) is also connected to R. For cooling, the furnace usually selects the high speed of the blower. In conventional heating which is oil or gas, the furnace controls the fan, so only R is connected to W (heat). For electric heating, the thermostat controls the fan (G), thus in this case both G (Fan) and W (heat) are connected to R (24 VAC). For heating applications, a lower blower speed is used and the furnace selects it. The furnace controls the fan because oil and gas heat is not instantaneous. In order to avoid a blast of cold air, the furnace controls the fan. It can do this with a simple delay or by temperature set by the limit switch in the plenum. Humidification is a fan-only function; humidifiers may be controlled by the G (fan) terminal.
Rc and Rh have been added to accommodate separate transformers for cooling and heating, respectively. Thus, for single transformer systems, Rc and Rh are jumpered together and assume the function of the R terminal. Some systems use R and Rc; so consider R to be Rh in this case. Rc is defined as R (cooling) and Rh is defined as R (heating). Often, both letters are in uppercase as in RC and RH. To run the fan, the thermostat connects the Fan (G) terminal to R. On thermostats with multiple R terminals (for example Rh and Rc), G is usually switched to Rc, although the "Gas/Electric" switch, if it exists, may change this. The Common (C) terminal has been a recent addition because modern electronic thermostats need power to operate. (Early thermostats did not require power because they used either mechanical snap-action switches or switches containing the liquid metal mercury. Mercury is a hazardous material and must be disposed of properly.) Together with the R terminal, Common provides always-on power to run the thermostat.
There is a technology called “power sharing” where unopened switches can power the thermostat. The current available is limited by the resistance of the furnace relays and may not be sufficient to run some thermostats (e.g. Nest). Some electronic thermostats are powered by a set of batteries. In this case no C terminal is required, but when the batteries die you have no air conditioning or heating. Programmable thermostats require a way to know the time and it needs to know the time during power outages. A thermostat may contain a small lithium battery just as your laptop or PC does. The manufacturer usually doesn’t even tell you about them. “Remove/pull this paper” before use is a good indication that the thermostat contains an internal battery. The battery may be rechargeable or it can be implemented using a supercap or Super capacitor. These are very high value capacitors which can run the clock for maybe a day or so. Your setpoints in an electronic thermostat are not susceptible to being lost when the power fails because they are stored using a different technology.
The technology is continually evolving, but the lifetime may be 10 years or more with say 15,000 write cycles. In many heating systems (especially those with heavy radiators), there is a great deal of "stored heat" in the system once it's hot, so the inside temperature will continue to rise for some time after the system turns off. If the thermostat were to wait until the desired temperature were reached before shutting off the system, that stored heat would continue to heat the building, overshooting the desired temperature by several degrees. To prevent this, old mercury thermostats used to pass a specific current through the bi-metallic spring to artificially raise its temperature, so the heat cuts off sooner. This way, when the heating system releases its stored heat into the building, the desired temperature is reached. The spring tension provided the hysteresis so that if the stat was set at 72, it would turn on for heat at 70 and it would turn off at say 71. The system would then "coast" up to the desired 72 or 73 due to the stored heat.
Modern thermostats often control this in a different way, using settings like "swing" or "cycles per hour". Some thermostats will calculate the stored heat automatically and adjust themselves accordingly. While not likely used on a home furnace - One of the most used methods of control is the PID algorithm. PID stands for Proportional Integral Derivative. The proportional term operates directly on the difference between the current value and the setpoint. This gets you close set point. The Integral terms operates on a running summation between setpoint and the current current value. This essentially ensures you get to the setpoint. The Derivative term operates on the rate of change of the difference between the set point and the current value. This allows a final tuning of the algorithm so to remove over/undershoot of the set point for maximum comfort. Thermostats can automatically find the values of P, I and D, but it may take it some time. This is called auto-tuning. By using auto-tune algorithms the thermostat can have a better chance of being at say 68 deg at 8:00 when you program that time and temperature.
Thermistors are a common way to measure temperature. These are temperature dependent resistors with a non-linear known behavior and they are cheap and not polarity sensitive. They may be used as external temperature sensors so that it can measure the outside temperature or control the temperature at a different place than where the thermostat is located. Solid state sensors could also be used and would most likely be used inside the thermostat. The outside temperature should be known to a heat pump control so it can measure what’s called a “balance point”. The balance point is when the heat pump output is just equal to the heat loss required to heat the home. At the balance point the heat pump will run all the time just to break even. If the outside temperature gets below this balance point, then supplementary electric or other heat is required to maintain the inside temperature. There is also an outside cut-off temperature where below that temperature the heat pump is no longer economical and only the supplementary heat should be used.