Now, I have to ask...ice or frost? A layer of frost is not a problem, most units are factory programmed to 'de-frost' about every 90 minutes. A layer of ice is a problem. This invariably is a dilemma with heat pumps. It's probably a malfunctioning defrost control which could cost between $350 and $1,000 to replace. The temporary fixes you can try prior to your service technician arriving are: Go to your thermostat and switch it to 'cooling'. This puts the unit effectively into defrost mode. Once the ice has melted, return it to the heat position. String some Christmas lights on the unit, the warmth from the bulbs will keep the ice from forming. Do not use the new LED Lights for this, they don't generate enough heat to work. Make sure this string of lights is plugged into a GFCI protected circuit. Shine large workshop type spotlights onto the unit. Know this about your heat pump: On a cold, wet morning it is only going to warm your inside air about 20 degrees when measured at the supply register.

That means if your thermostat is set at 70 degrees and your unit is maintaining that temperature, the air temp at the supply register won't be over 90 degrees. That's cooler than your body temperature, it will not feel like the heat is on.
how does aircon work in a car For that reason, we tell people never adjust the heat pump thermostat throughout the day.
how to turn on ac unit outsideYou cannot wake up in the morning and ask your unit to raise the temperature while you get ready for work and then drop the setting to let it rest while you are gone.
commercial ac unit sizing For heat pumps in winter, pick a livable temperature and leave it there until the spring, it is how the unit was designed to work. Our thanks to Green Valley Heating and Cooling and Yavapai Heating and Cooling for their photos.

Energy Savers is proud to announce our participation in Breast Cancer Awareness, Susan G. Komen program in October. This is an important cause to many as they strive to save lives by meeting the most critical needs to the community and investing in breakthrough research to prevent and cure breast cancer. We are so happy to announce that two of our very own, Annita Whatley and Angelia Davidson are winning the battle against Breast Cancer! Learn More About The Organization Air Conditioning, AC Repair, Cooling, HVAC Service & HeatingPhenix City, AL, Hamilton, GA, Ladonia, AL, Manchester, GA, Auburn, AL & Smiths Station, AL Success is built on relationships. By serving our friends and neighbors in Columbus and across Columbus, GA, Auburn, AL, Opelika & Phenix City, AL with the highest level of professionalism, Energy Savers continues to expand our list of valued customers. Through a consistent demonstration of exemplary performance on independent customer satisfaction surveys, and by meeting rigorous standards in business practices, technical expertise, and industry dedication, Energy Savers is recognized as a Carrier Factory Authorized Dealer.

This recognition is earned rather than given, and less than 5% of heating and cooling providers in the country receive this distinction. Through continued factory training in all areas of service and techniques, we are experts on the systems we install, maintain, and repair, assuring rewarding results. A team you can trust for your heating and cooling services! Columbus, GA, Auburn, AL, Opelika & Phenix City, AL Letter grades represent the Better Business Bureau’s rating of businesses based on customer service, time in business, required licenses, business practices, and number of complaints filed, with A+ being the highest. Energy Savers is extremely proud of our complaint-free, A+ rating, as it evidences our unwavering commitment to customer satisfaction. We are active members of the Columbus, Phenix City, Opelika and Auburn Chambers of Commerce as well as the Kiwanis Clubs in Columbus and Opelika. Energy Savers is BPI certified. The Building Performance Institute (BPI) is the nation’s leading standards development and credentialing organization for residential energy auditing and upgrade work.

BPI certified technicians have passed exacting written and in-field practical tests that demonstrate their knowledge and skills in building science solutions. BPI professionals utilize innovative and effective strategies to improve energy efficiency, while providing vital safety services, such as mold prevention, CO testing, and combustion appliance checks. For professional HVAC service, repairs, and installations, and air quality solutions, contact Energy Savers today! As your single resource for all of your temperature and air quality needs, Energy Savers specializes in the design, installation, maintenance, and repair of a wide variety of products, including furnaces, boilers, air conditioners, heat pumps, ductless HVAC, and air quality solutions. We offer free estimates, maintenance plans, emergency services, duct sealing and cleaning, whole-house comfort checkups, crawlspace retrofitting, new construction installation, HVAC system replacements, and more! We stand behind our work with 100% Satisfaction Guarantees, and deliver the timely, courteous, and honest service you expect and deserve.

Trust us to keep you perfectly comfortable at lower costs. Family owned and operated, Energy Savers has been saving East AL and West GA energy and money since 1977. Cooling • Heating • Air Conditioning • Manchester, GASometimes you may notice that your air conditioner freezes up after some time of operation. When this happens, the cool air will not be discharged properly and eventually a huge block of ice may built up on the evaporator coil. You will notice that there is less airflow coming from the air ventilation as ice began to clog the air movement. More condensation can be seen at the drain pan. At the same time, the room is no longer cool. This means that it is time to investigate the causes of this problem. Here are some possible causes. When air flow or air circulation from the unit to the room and vice versa is restricted, the exhange of thermal energy between the air conditioner and the room is restricted. As a result, most of the cool air continues to stay around the evaporator coil and fins causing the temperature around them to drop.

As a result, ice is formed and gradually more ice began to built up and eventually causes the air conditioner freezes up. Air Filters at the return air of the equipment must be serviced regularly by taking them down and wash with water and soap. These filters are used to trap dust and other bigger contaminants from going into the evaporator fins. Hence, cleaning them at least one or twice a month is highly recommended. In many cases, users will not even clean them once a year until this problem begin to surface.Evaporator coil and fins that are located after the air filters can also be clogged up due to dirty filters. In this case, you will need to clean them by using a spray type coil cleaner. The other alternative is to get the technicians to come and take down the entire evaporator for cleaning. This will be more costly. Therefore, regular maintenance of the evaporator coil and air filters will go a long way in ensuring that your air conditioner continues to function properly.Fan or blower at the evaporator unit may not be functioning.

When the unit is on, check that there is air flow coming out of the equipment. Otherwise, the fan may be damaged. In this case, the fan motor may have burnt or some loose connections may have occurred. Get a technician to check if this is the case.Check that there is no blockage of air around the evaporator by ensuring that things are not placed too near to the evaporator.One other step you can do is to check the set temperature of the air conditioner. Make sure that it is not set lower than 70 °F. When the refrigerant in the system is low due to leakage over time, there will be a decrease in the saturation point temperature of the system. When this happens, it will take a lower temperature for all the refrigerant liquid that has been compressed by the compressor to become vapor in the evaporator. This means that the operating temperature of the cooling coils has now dropped compared to the original design. This lower temperature will cause moisture collected from the air to quickly becomes ice on the evaporator when the temperature goes below below 32 °F.

These moisture that is supposed be cooled to a level which becomes water and drips to the condensate drainage pan is now stuck at the evaporator coils and fins forming ice around them. When this continues on, eventually a block of ice is formed on it. When you see the ice being formed on the evaporator, off the unit and wait for the ice to melt. It could take a few hours for all the ice to melt. A faster way is to on the air conditioner but using Fan mode. That means, only the fan is operating but the compressor is off. This will reduce the melting time of the ice but you will need to be around to monitor it as water may overflow and cause damage to your furniture or electrical items.A low refrigerant problem can only be solved by a qualified HVAC technician as additional refrigerant will have to be added to the system. Another possible cause is when you are operating your air conditioner when the outdoor temperature outside the house is low. When this happens, try to run the air conditioner using fan mode or simply use the outside air to ventilate your room.