ac sheet unit weight

Two motors means The MACH 8 DELIVERS the same high BTUs of cooling on both high and low speed operation. The Mach 8 has the HIGHEST air flow delivery on high speed, and ULTRA QUIET on low speed for night time cooling. Industry EXCLUSIVE molded one piece fiberglass base pan provides excellent durability with reduced weight. Mach 8 - Cub Mach 8 - 13,500 Mach 8 - 15,000 MACH 8 Rooftop A/C Installation Instructions MACH 8 Rooftop A/C Operation & Maintenance Instructions Limited Two Year A/C Warranty - Domestic U.S. MACH 8 Product Literature MACH 8 International Installation Instructions MACH 8 International Data Sheet LG LIVE Order History Welcome Sign out /Cool your home and control humidity levels by installing a window A/C unit Before you install a window A/C unit, make sure the window is sound and sturdy enough to support the weight of the air conditioner. If there’s any rot or damage, make the necessary repairs first. Also remember to place your unit near an electrical outlet as it is unsafe to connect your it using an extension cord.
WHAT YOU NEED FOR THIS PROJECT • Attach mounting brackets for support using wood or sheet-metal screws. • Slide accordion panels onto both sides of the A/C unit. • Place the A/C unit onto the mounting brackets. • Lower the window on top of the A/C unit. • Extend accordion panels and screw them into place. • Fill gap between lower sash and window pane with foam weather stripping. • Plug in the A/C unit, push the power button and set desired temperature. • Measure the width of the window and apply foam weather stripping. • Adjust the window bracket and secure it using L-shaped brackets. • Lower the window. • Connect both ends of the vent hose. • Plug in the portable A/C unit, push the power button and set to desired temperature. Tip: Remember to clean the filter and drain condensate water regularly. The DCA25SSI offers a prime rating of 20 kW (25 kVA) and a standby rating of 22 kW (27.5 kVA). 
Our patented open delta generator winding provides precise voltage control, allowing superior motor starting capability.  The mechanical governor maintains steady state 60 Hz within 3-5% from no load to full load. The unit features a powder-coated, weatherproof steel housing that allows a substantially low operating noise level of 63 dB(A). A comprehensive analog control panel provides instrumentation including AC ammeter, AC voltmeter, frequency meter, AC circuit breaker, engine gauges and much morehome ac unit making noise Voltage - Three Phasewall unit air conditioners on sale 208, 220, 240, 416, 440, 460, 480V Switchableair conditioner window unit not cold Voltage - Single Phase 120, 127, 139, 240, 254, 277V Switchable
Revolving field, Self-ventilated, Drip-proof, Single bearing Voltage Regulation (No Load to Full Load) Star with Neutral/ Zig Zag Frequency Regulation (steady state load) Sound Level (Full Load at 23 ft.) EmissionsEPA Interim Tier 4 Certified Design 4-cycle, Water cooled, Direct injection Gross Engine Power Output34.3 bhp25.5 kW Fuel Tank Capacity 17.0 gal 65.0 L Full load1.66 gph6.3 lph 3/4 load 1.21 gph4.6 lph 1/2 load0.85 gph 3.2 lph 1/4 load0.58 gph 2.2 lph Coolant Capacity1.74 gal6.6 L Oil Capacity 2.25 gal8.5 L Battery12V 53Ah x 1 Gross Vehicle Weight Rating (GVWR) Gross Axle Weight Rating (GAWR) (ea.) Tire Load Rating (ea.) 5 Lug on 4.5 in Fits MQ Power Generator Models TRLR50XF Dimensions & Weights With Fuel801 lb363.6 kg Without Fuel510 lb231.5 kgFor added safety and convenience the Fluke 381 Clamp Meter + detachable display allows you to take readings remotely or in tough-to-reach spots.
Fluke 381 Remote Display True RMS AC/DC Clamp Meter with iFlex® For added safety and convenience the Fluke 381 Clamp Meter + detachable display allows you to take readings remotely or in tough-to-reach spots. Overview Features Reviews Specs Models Accessories What Once Took Two People, Now Takes One Now one technician can do jobs that would otherwise require two people. Clamp the Fluke 381 around a conductor, remove the display and walk across the room to operate controls or remove protective equipment, all while watching real-time readings. The iFlex® Flexible Current Probe (included) expands the measurement range to 2500 A AC while providing increased display flexibility. With a cord that runs 6 feet, you can finally measure those tight spaces, awkward sized conductors and disorganized wires. Wireless technology allows the display to be carried up to 30 ft. away from the point of measurement for added flexibility without interference with measurement accuracy
The removable magnetic display can be conveniently mounted where it is easily seen iFlex® Flexible Current Probe expands the measurement range to 2500 A AC CAT IV 600 V, CAT III 1000 V Integrated low pass filter and state-of-the-art signal processing allows for use in noisy electrical environments while providing stable readings Proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it Ergonomic design fits in your hand and can be used while wearing protective equipment Radio transmitter automatically sets the correct measurement range so you do not need to change the switch positions while taking a measurement Safety Conformance IEC/EN 61010-1:2001, 1000V CAT III, 600V CAT IV AC Current via Jaw 2% ± 5 digits (10-100 Hz) 5% ± 5 digits (100-500 Hz) Crest Factor (50/60 Hz) 3 @ 500 A 2.5 @ 600 A 1.42 @ 1000 A Add 2% for C.F. > 2 AC Current via Flexible Current Probe
999.9 A / 2500 A (45 Hz – 500 Hz) 0.1 A / 1 A 3% ± 5 digits 3.0 at 1100 A 2.5 at 1400 A 1.42 at 2500 A Add 2% for C.F. > 2 0.5 in (12.7 mm) 1.4 in (35.6 mm) 0.8 in (20.3 mm) 2.0 in (50.8 mm) 2.5 in (63.5 mm) Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range. 2% ± 5 digits 600 V /1000 V 0.1 V / 1 V 1.5% ± 5 digits (20 – 500 Hz) 600.0 V /1000 V 1% ± 5 digits Frequency – Via Jaw 5.0 – 500.0 Hz 0.5% ± 5 digits 5 – 10 Hz, ≥ 10 A 10 – 100 Hz, ≥ 5 A 100 – 500 Hz, ≥ 10 A Frequency via Flexible Current Probe 5.0 to 500.0 Hz 5 to 20 Hz, ≥ 25 A 20 to 100 Hz, ≥ 20 A 100 to 500 Hz, ≥ 25 A 600 Ω/6 kΩ/60 kΩ 0.1 Ω/1 Ω/10 Ω Size (L x W x H) 277 x 88 x 43 mm (55 mm for remote unit) Flexible Current Probe Diameter Flexible Current Probe Cable Length (head to electronics connector)
Non condensing (< 10°C) ≤ 90% RH (at 10°C to 30°C) ≤ 75% RH (at 30°C to 40°C) ≤ 45% RH (at 40°C to 50°C) (Without Condensation) EMI, RFI, EMC, RF EN 61326-1:2006, EN 61326-2-2:2006 ETSI EN 300 328 V1.7.1:2006 ETSI EN 300 489 V1.8.1:2008 FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249 FCCID: T68-F381 RSS-210 IC: 6627A-F381 Add 0.1 x specified accuracy for each degree C above 28°C or below 18°C 2.4 GHz ISM Band 10 meter range ANSI/ISA S82.02.01:2004 CAN/CSA-C22.2 No. 61010-1-04 IEC/EN 61010-1:2001 to 1000V CAT III, 600V CAT IV. Fluke 381 Remote Display True RMS AC/DC Clamp Meter with iFlex® 18-inch iFlex® flexible current probe Five AA Alkaline batteries Fluke Handheld Instruments CarePlans Fluke C345 Soft Carrying Case Fluke C550 Tool Bag Fluke AC220 SureGripTM Alligator Clips Fluke AC87 Heavy Duty Bus Bar Clip Set Fluke AC89 Heavy Duty Insulation Piercing Test Clip Fluke LVD1 Volt Light