ac power distribution unit

AC Switched Power Distribution Unit (PDU) Now available to meet the NFPA 79 Category-0 Emergency Stop Standard! The AC SMARTStart® power distribution and power sequencing series is designed to remotely control AC loads and monitor vital parameters such as line voltage, total load current, and line frequency via Telnet, SNMP, or Web interface. Options inslude the Standard AC SMARTStart® for data centers, the Rugged AC SMARTStart® for wide operating temperatures, and the 3 Phase Power Distribution Unit for high power needs. What type of Power source does your project need?Emerson Network Power > EMEA > Products > By Type > Racks and Integrated Solutions > Emerson Network Power designs reliable and efficient Power Distribution Units (PDU) for a range of requirements. Liebert MPX Adaptive Rack Power Distribution Unit™MPH2 - Managed Rack PDUMPE Rack PDU​The MPE Rack PDU is a power distribution unit for data center applications. It provides all the requisite functionality of a rack-based power distribution unit and ensures that power is distributed reliably.
It can be connected up to all manner of IT equipment and other sensitive devicesLiebert MPH Managed Rack Power Distribution UnitAvocent PM 1000/2000/3000 Rack PDUsKnürr DI-STRIP Basic Rack PDUsInline Metering System (IMS)Knurr PowerTrans 19" Power Distribution Rack DPAC1U Series AC circuit breaker panels provide AC distribution and overload protection for two to eight circuits. They may also be used with other inverters or AC power sources. The maximum output current capacity from each A or B section is 50A, or a total of 100A from both. Individual circuit breaker capacities may be chosen from 5A to 30A for Option T or 5A to 15A for Option C. Any combination of breakers may be selected as long as the total current capacity of 50A for each section is not exceeded. In the standard dual model (with sections A and B) the two sections are connected in common (parallel). An optional model is available with the A and B sections isolated. There is a choice of barrier terminal strip input and output connectors (Option T) or NEMA 5-15R output receptacles with Positronics input connectors (Option C).
The panels are only one rack space (1.75 inches) high and come with brackets that permit mounting in either a 19- or 23-inch relay rack. They can be mounted from the front of the rack with offsets every quarter inch front to back to align with existing rackmounted equipment.best central heat air conditioning units One Rack Space High: 1.75”much will 4 ton ac unit cool 19- or 23-Inch Rack Mountingwindow ac units dimensions Terminal Block or NEMA 5-15R Outputs Voltage: 120VAC or 230VAC Nominal Up to 8 AC Circuits with Breakers Single (A) or Dual (A & B) Sections 50A AC Per Section (100A Total) Common or Isolated A & B Sections A & B Can Be Separately Configured AC Breaker Capacities: 5A to 30A
Up to 4 Inverter Inputs Rack Offset Every ¼” from Front to Back Single (A) or Dual (A & B) Sections 50A Per Section, 100A Total 2 to 4 Per Section, Up to 8 Total Option T: 5A to 30AOption C: 5A to 15A UL60950-1, CSA22.2 No.60950-1, EN60950-1 -40°C to + 85°C 0% to 95%, Non-Condensing 1.75 H x 17.13 W x 11.00 D (44.5 x 435 x 279) 10.25 lbs. ( 4.65 kg.) 19 or 23 Inches Option T: Barrier Terminal Strips Option C: Positronics/NEMA 5-15R Note: See ordering guide on datasheet to specify full model numbers Did you find what you are looking for? Find the right CyberPower product to fit your needs. CyberPower Basic Power Distribution Units (PDUs) provide reliable unfiltered power distribution from a UPS system, generator, or utility source to multiple devices. To ensure power availability, Basic PDUs do not include features such as surge suppression or line filtering which could interrupt the flow of power to connected equipment.
The Basic PDU Series includes models in 1U and 0U options, with versatile outlet arrangements on the front and/or back. Series features include durable metal housing, horizontal/vertical mounting, switch-free design, network-grade plugs and outlets, a power cord, and a cord retention tray. Each model comes with a Lifetime Warranty. CyberPower Metered Power Distribution Units (PDUs) provide network-grade power distribution. Each Metered PDU has a digital LCD meter for real-time load monitoring. Every Metered PDU comes with a Lifetime Warranty. CyberPower Monitored Power Distribution Units (PDUs) provide network-grade power distribution and remote/local monitoring. Power status can be monitored over the network, using the CyberPower Management Console and the RJ45 Ethernet port, or locally by using the digital LCD meter. Features of the Monitored PDU Series include upgradeable firmware, SNMP network interface, durable metal housing, and horizontal/vertical mounting. Monitored PDUs have switch-free design, network-grade plugs and outlets, a power cord, and a cord retention tray.
Every Monitored PDU comes with a Lifetime Warranty. Models in CyberPower's Switched PDU Series provide network-grade power distribution, remote/local monitoring, and outlet control. A Switched PDU allows for remote management, monitoring of PDU vitals, and control of outlets and networked clients. With the CyberPower Management Console, PDU outlets can be switched on and off to remotely reboot connected equipment. Also, planned power cycling of attached equipment can occur without disrupting performance. Features of the Switched PDU Series include upgradeable firmware, SNMP network interface, durable metal housing, and horizontal/vertical mounting. Switched PDUs have switch-free design, network-grade plugs and outlets, a power cord, and a cord retention tray. Every Switched PDU comes with a Lifetime Warranty. Designed for datacenters and other electrically demanding applications, CyberPower Metered Auto Transfer Switch (ATS) PDUs, distribute unfiltered electrical pass-through to receptacles from redundant plugs.
Dual power cords can be plugged into separate power sources to provide redundancy to single-corded connected equipment. If power for the primary source exceeds the lower or upper thresholds, or if power fails, the PDU will switch to the secondary power source to ensure continuous operation. The PDU will switch back to the primary power source when incoming power becomes stable. The current draw for connected equipment is displayed in amps on the front LCD for real-time load monitoring. Designed for datacenters and other electrically demanding applications, CyberPower Switched Auto Transfer Switch (ATS) PDUs, distribute unfiltered electrical pass-through to receptacles from redundant plugs. Outlets can be controlled remotely or locally, as well as individually or collectively. The LCD panel shows the current draw for connected equipment, input and output voltages, active power consumption levels (displayed in kilowatts), and hardware and firmware versions. Designed for datacenters and other locations where uptime is critical, CyberPower Maintenance Bypass PDUs allow the seamless transfer of an electrical load from UPS power to utility power for uninterrupted operation of connected equipment when performing maintenance, replacing batteries, or installing a new UPS.
The 6-foot AC cord of each Maintenance Bypass PDU (MBP) connects to utility power. A 3.3-foot AC cord connects to the output power of the UPS. The UPS draws input power from the MBP through a dedicated receptacle which is separate from the outlets for connected devices. When the switch on the front of the MBP is turned from Normal to Bypass, or from Bypass to Normal, the power supplied to connected devices moves from one input power source to another. An LED display indicates which power source is active. Rugged, industrial-grade metal housing protects the Maintenance Bypass PDUs. With a 1U form factor, each model can be mounted in a standard server rack. The mounting hardware also enables an MBP to be connected to a UPS for tower configurations. Each Maintenance Bypass PDU comes with a Three-Year Limited Warranty and a Connected Equipment Guarantee. Please enter the username or email associated with your My CyberPower account.You should receive an email shortly with information on how to change your password.
Acceptance of TermsPLEASE READ THE FOLLOWING TERMS AND CONDITIONS CAREFULLY The Channel Partner Alliance program (Program) from Cyber Power Systems (USA), Inc. (CyberPower) provides opportunities to each participating value added reseller (Participant). To join and use the Program, every Participant must agree to the following: • Participant has read, understands, and agrees to be bound by the terms and conditions of the Channel Partner Alliance Agreement (Agreement) and to any amendments to the Agreement, Program policies and procedures, which may be implemented or modified by CyberPower and communicated in writing to Participant from time to time. • Participant must not disclose any CyberPower information labeled as confidential while participating in the Program and for five (5) years thereafter. • Participant shall complete any training program required by CyberPower, including a one (1) hour online training module within one hundred and twenty (120) days of entering the Program;