Your browser is not supported. For the best experience, you should upgrade to a modern browser with improved speed and security. View full-size in new tab 40RUQA08A2A6-0A0A040RU = Packaged Air Handling Unit with Puron® R-410A RefrigerantQ = DX Coil for Heat Pump DutyA = None08 = 7.5 TonA = None - Standard2 = Std Static, Std Efficient Motor / Med DriveA = Standard Aluminum Fin / Copper Tube6 = 208/230/460-3-600 = StandardA = Standard0 = NoneA = Standard0 = StandardCarrier’s versatile packaged heat pump air-handling units satisfy design requirements with:Multi-position design for horizontal or vertical installation without modification.Standard sloped drain pans and cleanable insulation treated with Environmental Protection Agency (EPA) registered antimicrobial agent improve indoor air quality.High-static design meets a wider range of applications than competitive packaged air handler lines.Economizer accessory provides ventilation air and “free” cooling.Cooling coils with mechanically bonded fins provide peak heat transfer.
Hot water coil, steam coil, and electric heat accessories are available.Standard factory-installed thermo-static expansion valves (TXV) with removable power element on 40RUQ units.Die-formed galvanized steel casings provide durability and structural integrity. Optional paint is available.FEATURES / BENEFITSEasy-to-install and economical 40RU units provide reliable service.The 40RUQ Series units with direct-expansion coils are the best choice for packaged heat pump air handlers. All models offer excellent fan performance, a unique combination of indoor air quality features, easy installation, and affordable prices. how to charge central ac unitTheir versatility and state-of-the-art features will provide economical performance now and in the future.air conditioning units for a garageIndoor air quality featuresThe unique combination of features in the 40RUQ Series air handlers ensures that clean, fresh, conditioned air is delivered to the occupied space. heating and cooling units for wall
Cooling coils prevent the build-up of humidity in the room, even during part-load conditions. Two-inch (51-mm) disposable filters remove dust and airborne particles from the occupied space. Thermal insulation contains an immobilized anti-microbial agent to inhibit the growth of bacteria and fungi. The anti-microbial agent is registered with the U.S. Environmental Protection Agency (EPA). Pitched drain pan can be adjusted for a right-hand or left-hand connection to provide positive drainage and prevent standing condensate. Each unit contains two separate drain pans which are provided for either vertical or horizontal fan coil positions. Accessory economizer can provide ventilation air to improve indoor air quality. When used with CO2 sensors, the economizer admits fresh outdoor air to replace stale, recirculated indoor air.EconomyThe 40RUQ Series packaged air handlers have low initial costs, and they continue to save money by providing reduced installation expense and energy-efficient performance.
Quick installation is ensured by the multi-position design. Units can be installed in either the horizontal or vertical (upflow) configuration without modifications. All units have drain-pan connections on both sides, and pans can be pitched for right-hand or left hand operation with a simple adjustment. Fan motors and contactors are pre-wired and TXVs are factory-installed on 40RUQ models. High-efficiency, precision balanced fans minimize air turbulence, surging, and unbalanced operation, thereby cutting operating expenses. Economizer accessory precisely controls the blend of outdoor air and room air to achieve comfort levels. When the outside air enthalpy is suitable, outside air dampers can fully open to provide “free” cooling.Rugged dependabilityDie-formed galvanized steel panels ensure structural integrity under all operating conditions. Mechanically bonded coil fins provide improved heat transfer. Galvanized steel fan housings are securely mounted to a die-formed galvanized steel deck.
Coil flexibilityModel 40RUQ air handling units have galvanized steel casings; inlet and outlet connections are on the same end. Direct expansion (DX) coils are designed for use with Puron® R-410A refrigerant and have copper tubes mechanically bonded to aluminum sine-wave fins. Direct-expansion coils include matched, factory-installed thermostatic expansion valves (TXVs) with matching distributor nozzles.Easier installation and serviceThe multi-position design and component layout allow for quick unit installation and operation. The DX coils have factory-installed TXVs with matching distributor nozzles. Units can be converted from horizontal to vertical operation by simply repositioning the unit. Drain pan connections are duplicated on both sides of the unit. The filters, motor, drive, TXVs, and coil connections are easily accessed by removing a single side panel. Blower Motor HP2 1/2 HP Filter Size16 x 24 x 2 (Qty=4)Back in 2009, I had a new air conditioner installed our condo.
It wasn't cooling much, and the summer electric bills had risen. So, I did a Manual J load calculation on our condo to find out what size we should replace it with. There's this thing called summer design temperature, which is the temperature that your location goes above only 1% of the time. As I wrote in an earlier article about how to find out if your AC is oversized, I wanted to go with the 1.5 ton AC, but I chickened out and put in a 2 ton unit instead. Our place is about 1500 square feet, so that's 750 square feet per ton. That day was last Friday, 29 August, and I looked at the 24 hour period from midnight to midnight.The thermostat was at 75° F for nearly the whole day. The only time it wasn't was in the early morning morning when I lowered it to 74° F. Our design temperature in Atlanta is 92° F. Last Friday, we had a good 5 hours when the temperature stayed right there around 91-92° F. We had another couple of hours above 89° F, so it was perfect for seeing if our AC is oversized.