Building Supplies > HVAC > Ducting #82 in Home Improvement > Building Supplies > HVAC > Heaters & Accessories 103 pounds (View shipping rates and policies) 95 star89%1 star11%See all 9 customer reviewsTop Customer ReviewsThe best qualityGoodman GMS80804BN Gas Furnaces, is very good...! ! ! ! ! !Although I haven't installed it yet, it was extremely ...Arrived just a couple of days after ordering ...so therefore I'm satisfied with the purchaseFive StarsFive StarsFive Stars"> 40 Ton Ac Unit

40 ton ac unit

Goodman GMS80804BN Gas Furnace with 80% Afue, 80,000 Btu, 40 Ton Goodman LPM-06 Lp Conversion Kit for 2-Stage Gas Furnaces Goodman GMSS960803BN Single Speed 1-Stage Upflow/Horizontal Gas Furnace with Low Nox, 96% Afue, 80,000 Btu/H, 1,200 Cfm, 175" Width Goodman 10 KW Electric Furnace (34,120 BTU's) Mr. Heater F260550 Big Maxx MHU50NG Natural Gas Unit Heater 40 x 29 x 18.5 inches Power Tool Accessories, Welding Accessories, Gas Welding Accessory #34,284 in Home Improvements (See top 100) #46 in Home Improvement > Building Supplies > HVAC > Ducting #82 in Home Improvement > Building Supplies > HVAC > Heaters & Accessories 103 pounds (View shipping rates and policies) 95 star89%1 star11%See all 9 customer reviewsTop Customer ReviewsThe best qualityGoodman GMS80804BN Gas Furnaces, is very good...! ! ! ! ! !Although I haven't installed it yet, it was extremely ...Arrived just a couple of days after ordering ...so therefore I'm satisfied with the purchaseFive StarsFive StarsFive Stars
Goodman GMH80804BN Gas Furnace, Two-Stage Burner/Multi-Speed Blower, Upflow/Horizontal - 80,000 BTU Goodman GMH80803BN Gas Furnace, Two-Stage Burner/Multi-Speed Blower, Upflow/Horizontal - 80,000 BTUPackage HVAC Units For Sale Buy and Sell Used Package HVAC Units. Search by Manufacturers: Trane, Carrier, Lennox, York, Greenheckwindow ac units pros and consThe requested URL /cgi-bin/adpop.pl?880220 was not found on this server.heat pump unit not levelHome > Resources > FYI Library > FYI #073hvac unit 45 Process Cooling System Chiller and Tower Sizing Formulas TOWER SYSTEM DESIGN FORMULAS Cooling Tower = 3 Gallons per Minute per ton 1 Tower Ton = 15,000 BTU/hr Tower Ton = GPM x ΔT/30 Chiller = 2.4 Gallons per Minute / ton
1 ChillerTon = 12,000 BTU / hr Chiller Ton = GPM x ΔT / 24 LOAD SIZING FOR INJECTION MOLDING APPLICATIONS : MATERIAL 30# / hr H.D. Polyethylene = 1 ton 35# / hr L.D. Polyethylene = 1 ton 35# / hr Polypropylene = 1 ton 45# / hr PVC = 1 ton 50# / hr ABS = 1 ton 50# / hr Polystyrene = 1 ton 40# / hr Nylon = 1 ton 35# / hr Acrylic = 1 ton 40# / hr Polyurethane = 1 ton 50# / hr Acetal = 1 ton 40# / hr PPO = 1 ton 40# / hr PET = 1 ton 50# / hr Polycarb = 1 ton LOAD SIZING FOR INJECTION MOLDING APPLICATIONS : MACHINE Hydraulics = .1 ton/Horsepower Feed Throat = 1/2 ton each LOAD SIZING FOR EXTRUSION APPLICATIONS : Pipe, Profile, and Sheet 50# / hr H.D. Polyethylene = 1 ton 50# / hr L.D. Polyethylene = 1 ton 50# / hr Polypropylene = 1 ton 75# / hr Polystyrene = 1 ton 70# / hr PVC = 1 ton Extruder Barrel = 1 ton/inch of screw diameter Gear Box = 1 ton / 100 HP Feed Throat : diameter is < 3" = 1 ton
Feed Throat : diameter is > 3" = 2 ton Air Ring Cooling @ 105 CFM = 1 ton (50°F air @ 78°F WBT) LOAD SIZING FOR BLOW MOLDING APPLICATIONS 40# / hr Polyolefins = 1 ton (minimun Flow is 4.8 GPM / ton) Hydraulics = .1 ton / inch Feed Throat = 1/2 ton LOAD SIZING FOR OTHER EQUIPMENT Air Compressors with no after cooler = .1 ton / HP Air Compressor with after cooler = .2 ton / HP Vacuum Pump = .2 ton / HP Machine Tools = .2 ton / HP Water-Cooled Chiller = Each ton of chiller requires 1 ton of cooling tower Mold Temperature Controllers = 1.2 ton per zone + .2 ton/horsepower (heating) Mold Temperature Controllers = use PPH chart + .2 ton/horsepower (cooling) Spot Welders = 1/4 ton per tip (for chilled water) Plating Baths = Heat removal (BTU / hr) = DC amps x DC volts x 2.56 Mold Room Heating = 25 BTU / sq.ft. Non Mold Room Heating = 50 BTU / sq.ft. Mold Room Air Conditioning = 80 sq.ft / ton with 16' ceiling
LOAD SIZING FOR DIE CASTING Zinc = Heat removal (BTU / hr) = M x 95 BTU / lb             M = throughput rate (lbs / hr)             Pour at 800°F             Remove at 300°F Aluminum = Heat removal (BTU / hr) = M x 325 BTU / lb                     M = throughput rate (lbs / hr)                     Pour at 1200°F                     Remove at 900°F For each 1°F below 50°F LWT = 2% loss of rated chiller capacity Air Conditioning & Cooling As a temporary climate control company, cooling and air conditioning can be one component of controlling a space. Use ArcticDRY to provide cool, dry air, for example, in a warm and wet climate or working area to help provide a safer environment Sometimes worker safety requires cooling or the need to maintain a lower interior temperature calls for a DX unit to be added. If a project requires low humidity AND low temperature, enter the ArcticDRY.
Rather than 2, let’s use 1 The ArcticDRY unit is like incorporating an air conditioning unit and a dehumidifier together in one box. The ArcticDRY is a mechanical dehumidifier. Some people call it a process cooler. Other times it is referred to as a subcooled mechanical dehumidifier. Whatever you want to call it, this unit is extremely effective in warm climates and extremely popular. In addition to offering air conditioning/DX units, DRYCO exclusively offers the ArcticDRY unit – a mechanical dehumidifier unit that cools and dries. The ArcticDRY unit is NOT an air conditioner, but a unit that delivers cold air (like an air conditioner) but the key is that the ArcticDRY unit is built to remove moisture. For now, this unit is offered in 3 different sizes, a 15ton, 30ton and 60 ton (2,000cfm, 5,000cfm and 15,000cfm respectively). The ArcticDRY is sure to provide the cool, dry air needed in a warm & wet climate/environment. If you’re interested in one of these units and its hot outside, call now, as they usually go quickly!