3 ton package ac unit

2.5 Ton - 3.0 Ton Goodman 2.5 Ton 14 SEER Electric Heat Package Unit - GPC1430H41C Goodman 3.0 Ton 14 SEER Electric Heat Package Unit - GPC1436H41C Goodman 2.5 Ton 14 SEER Heat Pump Package Unit - GPH1430H41 Goodman 3.0 Ton 14 SEER Heat Pump Package Unit - GPH1436H41 Goodman 2.5 Ton 14 SEER 40K BTU Packge Unit with Gas Heat- GPG1430040M41A Goodman 2.5 Ton 14 SEER 60K BTU Packge Unit with Gas Heat - GPG1430060M41A Goodman 3.0 Ton 14 SEER 40K BTU Packge Unit with Gas Heat - GPG1436040M41A Goodman 3.0 Ton 14 SEER 60K BTU Packge Unit with Gas Heat - GPG1436060M41A Goodman 3.0 Ton 14 SEER 80K BTU Packge Unit with Gas Heat - GPG1436080M41A Goodman 2.5 Ton 15 SEER Heat Pump Package Unit Goodman 3.0 Ton 15 SEER Heat Pump Package Unit Rheem 2.5 Ton 14 SEER Electric Heat RACA Series Package Unit Rheem 3.0 Ton 14 SEER Electric Heat RACA Series Package Unit Single-Packaged Products with Energy-Saving Features and Puron® refrigerant.15.0-16.0 SEER / 12.0-12.5 EERSFactory-Installed TXVMulti-speed ECM Blower Motor - StandardSound levels as low as 72dBATwo Stages of CoolingDehumidification FeatureFeature / BenefitsOne-piece cooling unit with optional electric heater, low sound levels, easy installation, low maintenance, and dependable performance.

Puron Environmentally Sound Refrigerant is Carrier’s unique refrigerant designed to help protect the environment. Puron is an HFC refrigerant which does not contain chlorine that can harm the ozone layer. Puron refrigerant is in service in millions of systems proving highly reliable, environmentally sound performance.Easy InstallationFactory-assembled package is a compact, fully self-contained,electric cooling unit that is prewired, pre-piped, and pre-charged for minimum installation expense. These units are available in a variety of standard cooling sizes with voltage options to meet residential and light commercial requirements. Units are lightweight and install easily on a rooftop or at ground level. The high tech composite base eliminates rust problems associated with ground level applications.Innovative Unit Base DesignOn the inside a high-tech composite material will not rust and incorporates a sloped drain pan which improves drainage and helps inhibit mold, algae and bacterial growth.

On the outside metal baserails provide added stability as well as easier handling and rigging.
average cost of a window ac unitConvertible duct configurationUnit is designed for use in either downflow or horizontal applications.
how much is old ac unit worthEach unit is converted from horizontal to downflow and includes horizontal duct covers.
air conditioner outdoor unit placementDownflow operation is provided in the field to allow vertical ductwork connections. The basepan seals on the bottom openings to ensure a positive seal in the vertical airflow mode.Efficient operation High-efficiency design offers SEER(Seasonal Energy Efficiency Ratios) of up to 16.0.Durable, dependable componentsScroll Compressors have 2 stages of cooling and are designed for high efficiency.

Each compressor is hermetically sealed against contamination to help promote longer life and dependable operation. Each compressor also has vibration isolation to provide quieter operation. All compressors have internal high pressure and overcurrent protection.Multi-speed ECM Blower Motor is standard on all 50VG-A.Direct-drive PSC (Permanent Split Capacitor) condenser-fan motors are designed to help reduce energy consumption and provide for cooing operation down to 40ºF (4.4°C) outdoor temperature. Motormaster® II low ambient kit is available as a field-installed accessory.Thermostatic Expansion Valve - A hard shutoff, balance port TXV maintains a constant superheat at the evaporator exit (cooling cycle) resulting in higher overall system efficiency.Refrigerant system is designed to provide dependability. Liquid filter driers are used to promote clean, unrestricted operation. Each unit leaves the factory with a full refrigerant charge. Refrigerant service connections make checking operating pressures easier.

High and Low Pressure Switches provide added reliability for the compressor.Indoor and Outdoor coils are computer-designed for optimum heat transfer and efficiency. The indoor coil is fabricated from copper tube and aluminum fins and is located inside the unit for protection against damage. The outdoor coil is internally mounted on the top tier of the unit.Low sound ratings ensure a quiet indoor and outdoor environment with sound ratings as low as 72dBA.Easy to service cabinets provide easy 3 panel accessibility to serviceable components during maintenance and installation. The basepan with integrated drain pan provides easy ground level installation with a mounting pad. A nesting feature ensures a positive basepan to roof curb seal when the unit is roof mounted. A convenient 3/4-in. (19.05 mm) wide perimeter flange makes frame mounting on a rooftop easy.Dehumidification FeatureThis unit has independent fan speeds for low stage cooling and high stage cooling. In addition, 208/230 VAC models have thefield-selectable capability to run an enhanced dehumidification (’DHUM’) speed on high stage cooling (as low as 320CFM perton).

Coupled with the improved dehumidification associated with low stage cooling, the DHUM speed allows for a complete dehumidification solution independent of cooling stage. The dehumidification control must open the control circuit on humidity rise above the dehumidification set point. Blower Motor HP3/4 HP Condenser Motor HP1/5 HP Number of Fan Blades1You don't have permission to access /viewproduct.cfm?productID=453061932Of course, there are more than 3 reasons that your 3 ton air conditioner isn't really 3 tons, starting with the fact that it's not 3 tons in weight. I'm also not talking about any of the multitude of reasons having to do with improper design, faulty installations, or lack of maintenance, topics that I discuss plenty in this space. No, today I'm going to tell you that your 3 ton (or 2 ton or whatever size you have) air conditioner may not be what you think it is even when everything's designed, installed, commissioned, and maintained perfectly. So, what are these 3 reasons?

The first reason is that when we talk about air conditioner capacity, we're usually giving the nominal size. A 3 ton air conditioner has a nominal capacity of 36,000 BTU per hour, but the actual rating using the operating conditions specified by AHRI is rarely the same as the nominal capacity. For example, the AC shown in the AHRI certificate below is a 3 ton air conditioner (36,000 BTU/hr) with an actual capacity of 2.8 tons (34,000 BTU/hr). As David Butler discussed in his article on Manual S, AHRI ratings are done for an indoor dry bulb temperature of 80° F and indoor wet bulb temperature of 67° F. ACCA recommends using an indoor design temperature (dry bulb) of 75° F and relative humidity of 50%. Which way do you think it would go if we bring cooler air into the air conditioner than it was rated for? Well, let's frame that a little differently. If it's harder to cool air at 75° F than air at 80° F, then that means the 2.8 ton air conditioner above isn't even going to be 2.8 tons.

As David wrote, it's a moving target, but the net result of AHRI's operating conditions is that your air conditioner's capacity is lower than it's rated (unless you keep the thermostat at 80° F or higher). AHRI uses 95° F as its outdoor test temperature, so if your outdoor cooling design temperature differs from that, your AC capacity will again vary from the AHRI rated capacity. Our design temperature is 92° F, which means that the air conditoner has an easier job of dumping heat into the outside air than it would if it had to dump the heat into 95° F air. If you live in Tucson, Arizona, with a design temperature of 103° F, however, your 3 ton air conditioner has now dropped in capacity again. It's important to remember that the three reasons above don't have anything to do with poor design, installation, commissioning, or maintenance. A Manual J report may say you need a 3 ton air conditoner, but for the three reasons above, you might really need to install a 3.5 ton unit.