15 ton ac unit

What size air conditioner do I need for a 12 x 15 room? An air conditioner suitable for a 12 by 15 room has a minimum cooling capacity of 4500 BTU. Estimate this by multiplying the area of the room by a constant: 25 BTU. Therefore, 12 x 15 = 180 square feet. When 180 is multiplied by 25, the result is 4500. If a smaller air conditioning unit is used, it is going to run often and use a great deal of electricity. Even so, it is not likely to cool the room sufficiently. However, if an air conditioner is too large, it only does half of its job. As the appliance makes a room cooler, it also removes moisture from the air. A large air conditioner in a small room does not need to run very long, so too much moisture remains. This makes the cooler air feel humid or clammy. A 10,000 BTU air conditioner has 10,000 British Thermal Units of cooling capacity, or energy production required to remove heat from a room. This is a medi... How do you choose the right size air conditioner?

An air conditioner's capacity must be sized to fit the square footage of the room. If the air conditioner is too large, it turns off and on too quickly and... Why is BTU important when purchasing an air conditioning unit? The British thermal unit rating is a measurement of how much heat an air conditioner can remove from a room and is important in determining what size unit ...
average cost of an air conditioning unit Are ductless heat pumps worth the price?
1 ton ac cooling area How do you install a baseboard heater?
how many watts is an ac unit Where can you find air conditioner specifications online? What is the average testicle size? Are there any problems reported with a Ridge vent? How do you install a Coleman furnace?

Air Conditioning & Cooling As a temporary climate control company, cooling and air conditioning can be one component of controlling a space. Use ArcticDRY to provide cool, dry air, for example, in a warm and wet climate or working area to help provide a safer environment Sometimes worker safety requires cooling or the need to maintain a lower interior temperature calls for a DX unit to be added. If a project requires low humidity AND low temperature, enter the ArcticDRY. Rather than 2, let’s use 1 The ArcticDRY unit is like incorporating an air conditioning unit and a dehumidifier together in one box. The ArcticDRY is a mechanical dehumidifier. Some people call it a process cooler. Other times it is referred to as a subcooled mechanical dehumidifier. Whatever you want to call it, this unit is extremely effective in warm climates and extremely popular. In addition to offering air conditioning/DX units, DRYCO exclusively offers the ArcticDRY unit – a mechanical dehumidifier unit that cools and dries.

The ArcticDRY unit is NOT an air conditioner, but a unit that delivers cold air (like an air conditioner) but the key is that the ArcticDRY unit is built to remove moisture. For now, this unit is offered in 3 different sizes, a 15ton, 30ton and 60 ton (2,000cfm, 5,000cfm and 15,000cfm respectively). The ArcticDRY is sure to provide the cool, dry air needed in a warm & wet climate/environment. If you’re interested in one of these units and its hot outside, call now, as they usually go quickly! Copyright © 2015 DRYCO U.S.A. Website Design and Web Marketing By: Site Smart MarketingHDT Global > Products > Nordic Air® Industrial Products HDT Nordic Air is the worldwide product standard for heavy duty and severe duty environmental control units (ECUs) to industrial manufacturing and mining customers including steel mills, paper and pulp mills, coke plants, foundries, deep shaft mining operations, and other industrial businesses requiring air conditioning products designed and built to last in rugged and harsh manufacturing environments.

Strict adherence to ISO 9001:2008 standard requirements, extending to HDT Nordic Air subcontractors and suppliers Designs and builds air conditioning and humidity control units to withstand extreme conditions found in heavy duty/severe duty manufacturing facilities and mining operations HDT Nordic Air products are a significant upgrade compared to commercial-grade products that, when used in extreme environments, often have extremely short life cycles HDT Nordic Air products operate in extreme environmental conditions including: corrosive environments, high temperature and/or high humidity environments, excessive vibration environments, or Environments with extremely high levels of air-latent particulates Nordic Air products include: 2KR Series – Industrial grade window ECU with cooling capacity range of 16,000 BTU to 28,000 BTU Cabinet Cooler – Designed to cool sensitive electronic controls mounted in high ambient temperature, high dirt or highly corrosive environments.

Cooling capacities of 12,000 BTU, 18,000 BTU, and 24,000 BTU. Carolina Cooler – Portable air conditioner with cooling capacities ranging from 16K BTU to 60K BTU F-Series Filters – Highly efficient particulate filters designed for industrial applications HDE Series – Designed to operate in rugged heavy duty industrial environments, these water cooled air conditioning units are available in capacities of 3, 5, 8, 10, 15 and 20 tons HDR Series – Larger cooling capacities and additional standard features differentiate the HDR Series from the HDE Series SD Series – Handles the most abusive environments for air conditioning, filtering, heating, and ventilation under severe temperatures, extreme dirt, and corrosive conditions MBH400 Crane Cab Heater – A portable heater designed for use on overhead crane cabs where 240 Volt DC is the only available power supply I am trying to properly size a home generator and my concern is the start up amps on a 5 ton AC unit (15 years old R22 Goodwin type).

My home power is unique because we have 3 phase (the AC is on 3 phase breaker). I think the line to line voltage is around 240 and the line to ground approx 120 but the stinger leg (whatever you call it) is approx 207V to ground. The generator folk say 118 amps start up but that seem high to me not sure if he is just multiplying the steady state amps or what? Can you tell me how to determine it? For a hermetic compressor (what you most likely have in a unit of that size and vintage) -- the answer you seek is right on the compressor's nameplate, marked as "LRA", "Locked-Rotor Amps", under a "Locked Rotor" field, or in a similar fashion, as per NEC 440.4(A): The locked-rotor current of each single-phase motor-compressor having a rated-load current of more than 9 amperes at 115 volts, or more than 4.5 amperes at 230 volts, and each polyphase motor-compressor shall be marked on the motor-compressor nameplate. If you, somehow, have a compressor that uses an external motor drive, check the motor nameplate for the information from 430.7(B) point 8: